5.7 Frost protection 2. General information Electrical connection These instructions apply to the pump types TP and 6.1 Frequency converter operation TPD fitted with Grundfos motors. If the pump is fitted with another motor make, please note that the motor...
Pumps with lifting eyes must be lifted by means of 3. Delivery and handling nylon straps and shackles. See figures and 4. 3.1 Delivery The pump is delivered from the factory in a carton with a wooden bottom, which is specially designed for transport by fork-lift truck or a similar vehicle.
• cooling liquids However, some TP, TPE pumps of 11 kW and up • domestic hot water may be suspended directly in the pipes (horizontally •...
Page 5
If the liquid temperature falls below the ambient The motor must never fall below the temperature, condensation may form in the motor Caution horizontal plane. during inactivity. In this case, make sure that the drain hole in the motor flange is open and points For inspection and motor/pump head removal, the downwards.
1030 ≤ DN 200 TPD Series 300 pumps 1050 1050 For TP Series 300 pumps with weights of 150 kg or more, we recommend that you mount the pump on a 1000 1060 1060 concrete foundation with the dimensions stated in...
Pump weight two tapped holes in the bottom of the pump housing (height) (length) (width) [kg] which can be used for fitting a Grundfos base plate [mm] [mm] [mm] to the pump. The base plate is available as an 1400 optional extra.
Grundfos motors has been switched off. All three-phase Grundfos motors from frame size 90 Connect the pump to an external mains and up can be connected to a frequency converter. switch with a minimum contact gap of 3 The connection of a frequency converter will often mm in all poles.
7. Startup Open systems where the liquid level is below the pump inlet The inlet pipe and the pump must be filled with liquid 7.1 Flushing the pipe system and vented before the pump is started. The pump is not designed to pump liquids 1.
7.4 Starting 7.6 Frequency of starts and stops 1. Before starting the pump, completely open the isolating valve on the inlet side of the pump and Maximum number of starts per hour leave the isolating valve on the outlet side almost Frame closed.
7. Fit the coupling guards. which is injurious to health or toxic, the pump will be classified as contaminated. If Grundfos is requested to service the pump, Grundfos must be contacted with details about the pumped liquid, etc. before the pump is returned for service.
For the calculation of specific inlet pressures, contact the local Grundfos company or see the data 9. Technical data booklet for TP, TPD, TPE, TPED, TPE2, TPE2 D, TPE3, TPE3 D, if at hand. 9.1 Ambient temperature 9.5 Enclosure class Maximum 55 °C (131 °F).
10. Fault finding the product Warning Before removing the terminal box cover and before removal/dismantling the pump, make sure that the power supply has been switched off and that it cannot be accidentally switched on. Make sure that the escaping liquid does not cause injury to persons or damage to the motor or other components.
This product or parts of it must be disposed of in an environmentally sound way: 1. Use the public or private waste collection service. 2. If this is not possible, contact the nearest Grundfos company or service workshop. Subject to alterations.
Page 16
Appendix Inlet pressure stated in bar relative pressure (pressure gauge value measured on the suction side of the pump) Относително входно налягане в bar (стойност на манометъра в смукателната страна на помпата) Tlak na sání vyjádřený v barech je relativní tlak (hodnota na manometru měřená na sací straně čerpadla) Zulaufdruck in bar Relativdruck (Manometerdruck auf der Saugseite der Pumpe gemessen) Tilløbstrykket angivet i bar relativt tryk (manometerværdi målt på...
Page 34
Argentina China Hong Kong Bombas GRUNDFOS de Argentina S.A. GRUNDFOS Pumps (Shanghai) Co. Ltd. GRUNDFOS Pumps (Hong Kong) Ltd. Ruta Panamericana km. 37.500 Centro 10F The Hub, No. 33 Suhong Road Unit 1, Ground floor Industrial Garin Minhang District Siu Wai Industrial Centre 1619 Garín Pcia.
Page 35
Malaysia Serbia Turkey GRUNDFOS Pumps Sdn. Bhd. Grundfos Srbija d.o.o. GRUNDFOS POMPA San. ve Tic. Ltd. 7 Jalan Peguam U1/25 Omladinskih brigada 90b Sti. Glenmarie Industrial Park 11070 Novi Beograd Gebze Organize Sanayi Bölgesi 40150 Shah Alam Phone: +381 11 2258 740...
Need help?
Do you have a question about the TP and is the answer not in the manual?
Questions and answers