Commissioning the system
Parameters for pumps and other components
Parameter
Heating circuit pump
"System definition"
Ó
"System scheme 7000"
DHW circulation pump
Extended menu
Ó
"Time program DHW circulation"
Extension kit, mixer for heating circuit M2/HC2
"System definition"
Ó
"System scheme 7000"
Remote control for heating/cooling circuit
"Heating circuit 1"/"Heating circuit 2"
"Remote control 2003"
or
"Remote control 3003"
Remote control for separate cooling circuit
"Cooling"
Ó
"Remote control cooling circ 7116"
"Ranking room temp sensor separate cooling circuit 7106"
Vitocom 100, type GSM/GSM2
"System definition"
Ó
"Vitocom 100 7017"
External extension
"System definition"
Ó
"External extension 7010"
Commissioning, inspection, maintenance
(cont.)
Ó
Setting
With heating circuit A1/HC1 for heat-
ing circuit without mixer
or
With heating circuit M2/HC2 for
heating circuit with mixer
Set a time program.
With heating circuit M2/HC2
Note
Set rotary switch S1 in the extension
kit to "2": See "Mixer extension kit" in-
stallation instructions.
"1"
Note
Set code on the Vitotrol to assign
heating circuits:
See "Vitotrol" installation instructions.
"1"
"0" Connection F16
"1" Heating circuit A1/HC1
"2" Heating circuit M2/HC2
"4" Separate cooling circuit SKK
"1"
"1" EA1 extension
"2" AM1 extension
"3" EA1 and AM1 extensions
Note
Parameters for external functions: See
the following table.
47