56
NOTE: You must reset or
restart the APV200-IP to
enable any changes.
Aux Data Port
Select this option to configure the AUX DATA port for data or control
applications.
Mode
Select this option to change the operating mode of the AUX DATA port.
Sony camera
Canon camera
Panasonic
camera
VCR Type 1
Debug
(default)
Data
Null Modem
Test
AP400
Baud Rate
Select this option to set the rate in Kilobits per second (Kbps) the data
will flow through the aux data port. Consult the device manufacturer's
documentation for the proper selection.
300
1200
2400
4800
9600 (default)
Flow Control
Select this option to choose the data flow control method. Consult the
device manufacturer's documentation for the proper selection.
None
No flow control will be applied.
(default)
X-on/X-off
Software flow control will be applied.
RTS/CTS
Hardware flow control will be applied.
TECHNICAL SUPPORT: 1.800.283.5936 (USA) OR 1.801.974.3760
OPERATION • DATA PORT CONFIGURATION
Select this option for use with Sony PTZ cameras
with VISCA IN control port
Select this option for use with Canon VCC series
PTZ cameras with an RS232 control port.
Select this option for use with Panasonic PTZ
cameras with a Camera Control control port.
Select this option for use with a VCR equipped with
a Type 1 control port.
Select this option to obtain debugging logs using a
PC and HyperTerminal.
Select this option for data collaboration using
Microsoft's NetMeeting or the API.
Select this option for a pass through data pipe.
Reserved for factory testing.
Select this option to control the Gentner AP400
audioconferencing system.
19200
28800
38400
57600
115200