Digital Flow Switch with Pressure/Temperature Sensor
4-Screen Display
Specifications
Model
Applicable fluid
*
1
Fluid
Fluid temperature
Detection method
Rated flow range
Set point
Instantaneous flow
range *
2
Accumulated flow
Flow
Smallest settable
Instantaneous flow
increment
Accumulated flow
Accumulated volume per pulse (Pulse width = 50 ms)
Accumulated value hold function
Rated pressure range
*
Set pressure range
2
Pressure
Smallest settable increment
Proof pressure
Pressure loss
Rated temperature range
Temperature
Set temperature range
Smallest settable increment
Power supply voltage
Electrical
Current consumption
Protection
Flow rate
Accuracy
Pressure
Temperature
Accuracy
Repeatability (Flow rate/Pressure)
Temperature characteristics (Flow rate/Pressure)
Pressure characteristics (Flow rate)
Effects of connecting modular products (Flow rate)
Output type
Output mode
Switch operation
Max. load current
Switch
Max. applied voltage (NPN only)
output
Internal voltage drop (Residual voltage)
Response time
Delay time
*
8
Hysteresis
*
9
Protection
*
Reference condition
10
Instantaneous flow
Accumulated flow
Unit *
11
Pressure
Temperature
Instantaneous flow
Display
Accumulated
range
flow
Display
Pressure
Temperature
Instantaneous flow
Min. display
Accumulated flow
unit
Pressure
Temperature
Display
Indicator LED
Flow rate
Digital
Pressure
filter*
13
Temperature
Enclosure
Withstand voltage
Environmental
Insulation resistance
resistance
Operating temperature range
Operating humidity range
Standards
Piping
Piping specification
Main materials of parts in contact with
fluid
Length of lead wire with connector
Body
Weight
Lead wire with connector
Communication Specifications (IO-Link mode)
IO-Link type
IO-Link version
Communication speed
Configuration file
Minimum cycle time
Process data length
On request data communication
Data storage function
Event function
Vendor ID
Device ID *
15
Modular Type
PF3A801H
Air, Nitrogen
0 to 50°C
Thermal type (Bypass flow type)
10 to 1000 L/min
10 to 1050 L/min
0 to 9,999,999,990 L
1 L/min
Select from 10 L/pulse or 100 L/pulse.
*
3
Intervals of 2 or 5 minutes can be selected.
0.000 to 1.000 MPa
−0.050 to 1.050 MPa
0.001 MPa
1.5 MPa
Refer to the "Pressure Loss" graph on page 24.
0.0 to 50.0°C
−10.0 to 60.0°C
21.6 to 30 VDC
150 mA or less
Polarity protection
*
4
±3.0% F.S.
±3.0% F.S.
*
5
±2.5°C (Flow range: 100 to 1000 L/min, 200 to 2000 L/min)
±1.0% F.S.
±5.0% F.S. (Ambient temperature of 0 to 50°C, 25°C standard)
*
6
±5.0% F.S. (0 to 1.0 MPa, 0.5 MPa standard)
*
7
±5.0% F.S.
Select from NPN or PNP open collector. (2 outputs)
Hysteresis mode, Window comparator mode, Error output, Output OFF,
Accumulated output, Accumulated pulse output (Only flow rate)
Select from Normal or Reversed output.
80 mA
30 VDC
1.5 V or less (at load current of 80 mA)
5 ms or less
Variable from 0 to 60 s/0.01 s increments
Variable from 0
Over current protection
Select from Standard conditions or Normal conditions.
L/min, CFM (ft
MPa, KPa, kgf/cm
°C, °F
0 to 1050 L/min
*
12
(Flow under 10 L/min is displayed as "0")
0 to 9,999.99 x 10
0 to 9,999,999.99 x 10
*
12
−0.050 to 1.050 MPa
−10.0 to 60.0°C
1 L/min
0.001 MPa
LCD, 4-screen display
Upper line: Red/Green, Lower line: Orange
Upper/Lower line: 10 digits (7 segments 5 digits, 11 segments 5 digits)
OUT indicator: Orange LED is ON when output is ON
1 s (2 s or 5 s can be selected.)
0.1 s (Variable from 0 to 30 s/0.01 s increments)
1000 VAC for 1 minute between terminals and housing
50 MΩ (500 VDC measured via megohmmeter) between terminals and housing
Operating: 0 to 50°C, Stored: −10 to 60°C (No freezing or condensation)
Operating/Stored: 35 to 85% RH (No condensation)
CE marking (EMC Directive, RoHS Directive)
Modular (Body size: 30)
Stainless steel 304, Aluminum alloy, PPS, HNBR
[Sensor: Pt, Au, Ni, Fe, Lead glass (exempted from the RoHS application), Al
350 g
+90 g
Device
COM2 (38.4 kbps)
IODD file *
5.8 ms
Input data:12 bytes, Output data: 0 byte
131 (0 x 0083)
PF3A801H-L2
w
PF3A802H-L2
w
For flow switch precautions and specific product precautions,
refer to the "Operation Manual" on the SMC website.
PF3A802H
20 to 2000 L/min
20 to 2100 L/min
2 L/min
10 L
0.1°C
3
/min)
L, ft
3
, bar, psi
2
0 to 2100 L/min
(Flow under 20 L/min is displayed as "0")
6
L (6-digit display)
3
L (9-digit display)
2 L/min
10 L
0.1°C
1 s
IP65
Modular (Body size: 40)
O
]
2
3
3 m
400 g
V 1.1
14
Yes
Yes
Yes
-
: 562 (0 x 0232)
www
-
: 563 (0 x 0233)
www
PF3A8
H-L
w
*1 Air quality grade is JIS B 8392-1:2012 [4:6:-] and
ISO 8573-1:2010 [4:6:-].
*2 Set point range will change according to the
setting of the zero cut-off function.
*3 When using the accumulated value hold function,
use the operating conditions to calculate the
product life, and do not exceed it. The maximum
update limit of the memory device is 1.5 million
times. If the product is operated 24 hours per day,
the product life will be as follows:
· 5 min interval: life is calculated as 5 min x 1.5
million = 7.5 million min = 14.3 years
· 2 min interval: life is calculated as 2 min x 1.5
million = 3 million min = 5.7 years
If the accumulated value external reset is
repeatedly used, the product life will be shorter
than the calculated life.
*4 The value when connecting a product with a port
size of 3/8 (PF3A801H) or 1/2 (PF3A802H)
*5 In the low flow rate range, the temperature value
fluctuates (rises). Refer to the "Temperature
Accuracy" graph on page 25.
*6 Do not release the OUT side piping port of the
product to the atmosphere without connecting
piping. If the product is used with the piping port
released to atmosphere, accuracy may vary.
*7 The value when the port size of the modular
product is 3/8 (PF3A801H) or 1/2 (PF3A802H) and
the product is operated at a supply pressure of 0.5
MPa
*8 The time from when the measured value reaches
the set value to when the switch output operates
can be set.
*9 If the measured value fluctuates around the set
value, the width for setting more than the
fluctuating width needs to be set. Otherwise,
chattering will occur.
*10 The flow rate given in the specifications is the
value under standard conditions.
*11 Setting is only possible for models with the units
selection function.
*12 Display range will change according to the setting
of the zero cut-off function.
*13 The time for the digital filter can be set to the
sensor input. The response time indicates when
the set value is 90% in relation to the step input.
*14 The configuration file can be downloaded from
the SMC website, https://www.smcworld.com
*15 The device ID differs according to each product
type (output specification).
* Products with tiny scratches, marks, or display color
or brightness variations which do not affect the
performance of the product are verified as
conforming products.