Art-Net/sACN Trigger Preferences

Mbox Director scenes can be triggered using Art-Net or sACN. In this case, incoming values are compared to the
numerical values of scene names as entered in the Scene List. For example, a scene named '1.15 Top of Show' would
be triggered by sending the correct values for 1.15. (Note: Make sure to leave a space between any numerical prefix
and the letters in the scene name for this to function properly.)
To use the Trigger feature, it must be enabled at the Art-Net Trigger tab of the Preferences window. When enabled,
Director will listen for Art-Net or sACN on a specified Input Universe.
Triggering uses five (5) channels, starting at a specified channel offset. The five incoming channels are split into three
parts: one channel to enable/disable the trigger, two channels to provide a value before the decimal point, and two
channels to provide a fractional value after the decimal point. The values before and after the decimal point are
represented by 16-bit numbers (0-65535). The number before the decimal point is always interpreted literally.
However, depending on the setting for Cue # Fraction Digits (see next page), the value after the decimal point will be
interpreted differently.
To enable and configure Art-Net trigger:
Step 1. At Art-Net Trigger tab, click ArtNet Trigger Enabled checkbox.
Step 2. At Input Universe field, enter a universe number from 0 to 255.
Step 3. At Channel field, enter a starting channel from 1 to 508.