IM 01R01B02-01E-E, supplementary instructions to standard RAMC User´s Manual IM 01R01B02-00E-E
Y okogawa Electric Corporation
METER
ROTA
RAMC
Variable Area Flowmeter
PROFIBUS PA Communication Type
Rota Yokogawa GmbH & Co. KG
Rheinstr. 8
D-79664 Wehr
Germany
IM 01R01B02-01E-E
©
Copyright 2006 (RYG)
5th edition, October 2020 (RYG)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ROTAMETER RAMC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for YOKOGAWA ROTAMETER RAMC

  • Page 1 ROTA RAMC Manual Variable Area Flowmeter PROFIBUS PA Communication Type IM 01R01B02-01E-E, supplementary instructions to standard RAMC User´s Manual IM 01R01B02-00E-E Rota Yokogawa GmbH & Co. KG IM 01R01B02-01E-E © Rheinstr. 8 Copyright 2006 (RYG) D-79664 Wehr 5th edition, October 2020 (RYG)
  • Page 2: Table Of Contents

    5.4 Transducer Block (TB) Parameters ...............5-3 6. Status and Diagnostic Information ..........6-1 6.1 Status description ...................6-1 6.2 Diagnostics ......................6-3 6.3 Status impacts of Alarm settings ..............6-4 All Rights Reserved. Copyright © 2006, Rota Yokogawa IM 01R01B02-01E-E 5th edition October 01, 2020 -00...
  • Page 3 A2.1 Applications and Selection of Basic Parameters ........A-11 A2.2 Setting and Change of Basic Parameters ..........A-12 A2.3 Setting the AI Function Blocks ..............A-13 All Rights Reserved. Copyright © 2006, Rota Yokogawa IM 01R01B02-01E-E 5th edition October 01, 2020-00...
  • Page 4: Introduction

    IM01R01B02-00 -E. Before use, read this manual thoroughly and familiarize yourself fully with the features, operations and handling of Rotameter RAMC to have the instrument deliver its full capabilities and to ensure its efficient and correct use. All Rights Reserved. Copyright © 2006, Rota Yokogawa...
  • Page 5: About Profibus Pa

    RAMC PROFIBUS communication type employs the specification standardized by the PNO, and provides interoperability between Yokogawa devices and those produced by other manufacturers. 2.2 Internal Structure of RAMC PROFIBUS PA RAMC contains three function blocks which are implemented in accordance with Profile 3.02.
  • Page 6: Installation

    3) Cable shield on transmitter side recommended In case of insufficient cable shielding and grounding, degrading of EMC immunity is Terminator possible. Segment coupler Figure 3.1 Device Connection All Rights Reserved. Copyright © 2006, Rota Yokogawa IM 01R01B02-01E-E 5th edition October 01, 2020 -00...
  • Page 7 • If the fieldbus device is operated at ambient temperatures above +50 °C, the supply voltage of the device must be above 9.5 V. • For installation in hazardous area chapter 7 must be regarded. All Rights Reserved. Copyright © 2006, Rota Yokogawa IM 01R01B02-01E-E 5th edition October 01, 2020-00...
  • Page 8: Start Of Operation

    Sub-parameter: EU_at_100% Parameter: OUT_SCALE Set lower range limit (set to scale lower range as specified when ordered) Sub-parameter: EU_at_0% Parameter: CHANNEL 0x0111 (273) 0x0115 (277) All Rights Reserved. Copyright © 2006, Rota Yokogawa IM 01R01B02-01E-E 5th edition October 01, 2020 -00...
  • Page 9: Cyclic Data Exchange

    Factory default is totalizer. Pressing the "arrow right" button an error indication appears on display. • 00000000 or • 00000000 A detailed explanation see chapter 6. All Rights Reserved. Copyright © 2006, Rota Yokogawa IM 01R01B02-01E-E 5th edition October 01, 2020-00...
  • Page 10: Menu Structure

    Device Diagnosis Diagnosis Mask Diagnosis Device Diagnosis Diagnosis Extension Mask Extension Diagnosis Extension Diagnosis/Status Condensed Status/Diagnosis Configuration Serial Communication Failure Diagnosis Mapping: Status Mapping: All Rights Reserved. Copyright © 2006, Rota Yokogawa IM 01R01B02-01E-E 5th edition October 01, 2020 -00...
  • Page 11 Status Mapping: Volume Flow High Limit Diagnosis Mapping: Status Mapping: Mass Flow Low Limit Diagnosis Mapping: Status Mapping: Mass Flow High Limit Diagnosis Mapping: Status Mapping: All Rights Reserved. Copyright © 2006, Rota Yokogawa IM 01R01B02-01E-E 5th edition October 01, 2020-00...
  • Page 12 Operation Parameter Calibration Factor Nominal Size Nominal Size Unit Low Flow Cutoff Low Flow Cutoff Unit Operation Condition Density Viscosity Pressure Ref. Pressure Temperature Oper. Condition All Rights Reserved. Copyright © 2006, Rota Yokogawa IM 01R01B02-01E-E 5th edition October 01, 2020 -00...
  • Page 13 Alert Key Target Mode Actual Mode Block Object Parent Class Class No. of Parameters Current State Alarm Sum Batch ID Batch Unit Batch Operation Batch Phase All Rights Reserved. Copyright © 2006, Rota Yokogawa IM 01R01B02-01E-E 5th edition October 01, 2020-00...
  • Page 14 Lower Unack. Warning Lower Warning Status Lower Warning Output Value Lower Unack. Alarm Lower Alarm Status Lower Alarm Output Value Simulation Simulation Status Simulation Value Simulation All Rights Reserved. Copyright © 2006, Rota Yokogawa IM 01R01B02-01E-E 5th edition October 01, 2020 -00...
  • Page 15 Device Diagnosis Diagnosis Extension Mask Extension Diagnosis Extension Diagnosis/Status Condensed Status/Diagnosis Configuration Serial communication failure Diagnosis Mapping: Status Mapping: RAM Error Diagnosis Mapping: Status Mapping: All Rights Reserved. Copyright © 2006, Rota Yokogawa IM 01R01B02-01E-E 5th edition October 01, 2020-00...
  • Page 16 Volume Flow High Limit Diagnosis Mapping: Status Mapping: Mass Flow Low Limit Diagnosis Mapping: Status Mapping: Mass Flow High Limit Diagnosis Mapping: Status Mapping: All Rights Reserved. Copyright © 2006, Rota Yokogawa IM 01R01B02-01E-E 5th edition October 01, 2020 -00...
  • Page 17 Operation Parameter Calibration Factor Information Nominal Size Nominal Size Unit Low Flow Cutoff Low Flow Cutoff Unit Operation Condition Density Viscosity Pressure Ref. Pressure Temperature Oper. Condition All Rights Reserved. Copyright © 2006, Rota Yokogawa IM 01R01B02-01E-E 5th edition October 01, 2020-00...
  • Page 18 Static Revision No. Strategy Alert Key Target Mode Actual Mode Block Object Parent Class Class No. of Parameters Current State Alarm Sum Batch ID Batch Unit All Rights Reserved. Copyright © 2006, Rota Yokogawa IM 01R01B02-01E-E 5th edition October 01, 2020 -00...
  • Page 19 Lower Alarm Output Value Simulation Simulation Status Simulation Value Simulation Factory Reset TB Process Variable View Volume Flow Volume Flow Status Volume Flow Unit Flow Percent All Rights Reserved. Copyright © 2006, Rota Yokogawa IM 01R01B02-01E-E 5th edition October 01, 2020-00...
  • Page 20 Flow Percent Analog Input Block OUT Value OUT Status Diag- nostics Device Diagnosis Diagnosis Mask Diagnosis Extended Device Extended Diagnosis Diagnosis Mask Diagnosis Extension All Rights Reserved. Copyright © 2006, Rota Yokogawa IM 01R01B02-01E-E 5th edition October 01, 2020 -00...
  • Page 21: Block Setting

    • “2712”: Reset Address to 126. Other parameters are not affected. COND_STATUS_DIAG: This parameter allows changing of status and diagnosis handling: • “0”: Classic Status and Diagnosis • “1”: Condensed Status and Diagnosis All Rights Reserved. Copyright © 2006, Rota Yokogawa IM 01R01B02-01E-E 5th edition October 01, 2020 -00...
  • Page 22: Analog Input (Ai) Block Parameters

    • “1”: Value: last stored valid value, Status: UNCERTAIN - last usable value • “2”: Value: actual, Status: no adjustment NOTE Depending on COND_STATUS_DIAG setting the OUT status differs. All Rights Reserved. Copyright © 2006, Rota Yokogawa IM 01R01B02-01E-E 5th edition October 01, 2020-00...
  • Page 23: Transducer Block (Tb) Parameters

    1000 TEMPERATURE Indicates the indicator temperature value as selected by TEMPERATURE_UNIT. This parameter can not be used for cyclic communication on AI Function Block. All Rights Reserved. Copyright © 2006, Rota Yokogawa IM 01R01B02-01E-E 5th edition October 01, 2020 -00...
  • Page 24 Changing the flow unit will cause a reset of the actual totalizer value. The parameter TOTALIZER can not be used for cyclic communication on AI Function Block. All Rights Reserved. Copyright © 2006, Rota Yokogawa IM 01R01B02-01E-E 5th edition October 01, 2020-00...
  • Page 25 Standard cubic meter per hour (60 °F, 14.7 psia) 1598 m³/min std. m³/min std. Standard cubic meter per minute (60 °F, 14.7 psia) 1597 Not Active 32768 All Rights Reserved. Copyright © 2006, Rota Yokogawa IM 01R01B02-01E-E 5th edition October 01, 2020 -00...
  • Page 26 1330 LTon/d LTon/d Long ton per day 1341 LTon/h LTon/h Long ton per hour 1340 LTon/min LTon/min Long ton per minute 1339 Not Active 32768 All Rights Reserved. Copyright © 2006, Rota Yokogawa IM 01R01B02-01E-E 5th edition October 01, 2020-00...
  • Page 27: Status And Diagnostic Information

    0x0C … 0x0F out of service Value constant 0x1F out of service 0x1C Highest * Limits status information as defined in table 6.3 cause value ranges All Rights Reserved. Copyright © 2006, Rota Yokogawa IM 01R01B02-01E-E 5th edition October 01, 2020 -00...
  • Page 28 GOOD, maintenance demanded UNCERTAIN, maintenance demanded BAD, maintenance demanded UNCERTAIN, process related, no maintenance BAD, process related, no maintenance BAD, function check /local overrride GOOD, function check All Rights Reserved. Copyright © 2006, Rota Yokogawa IM 01R01B02-01E-E 5th edition October 01, 2020-00...
  • Page 29: Diagnostics

    Hardware failure of the electronic Maintenance required New start-up (warm startup) carried out Restart (cold startup) carried out Ident Number Violation More information available All Rights Reserved. Copyright © 2006, Rota Yokogawa IM 01R01B02-01E-E 5th edition October 01, 2020 -00...
  • Page 30: Status Impacts Of Alarm Settings

    Limit violations of the OUT value directly affect the limit bits and the status information of the OUT status. CAUTION To avoid unusable alarm status information, the upper alarm /warning limits must always be used above the lower alarm /warning limit. All Rights Reserved. Copyright © 2006, Rota Yokogawa IM 01R01B02-01E-E 5th edition October 01, 2020-00...
  • Page 31: Explosion Protected Type Instruments

    Only trained personnel may use the instrument in an industrial location. • The instrument modification or replacement of parts by other than an authorized Representative of Yokogawa is prohibited and will void the certification. • Electrostatic charge on painted or other non- metallic surfaces may cause an explosion hazard.
  • Page 32: Marking

    Ex ia IIB/IIC T6/T4 Gb PTB 12 ATEX 2003 X IECEx PTB12.0020X See certificate for data See certificate for data FISCO field device FISCO field device II 2G All Rights Reserved. Copyright © 2006, Rota Yokogawa IM 01R01B02-01E-E 5th edition October 01, 2020-00...
  • Page 33: Installation

    If all devices connected to the BUS in the hazardous area are locally grounded according to manaufacturers‘ specifications the Ground Bonding System could be avoided. Figure 7.2 Possibility 1: Shield grounded in hazardous and safe area All Rights Reserved. Copyright © 2006, Rota Yokogawa IM 01R01B02-01E-E 5th edition October 01, 2020 -00...
  • Page 34 Optional Ground Bonding System Optional ground (needed if Ground Bonding System not used) Acc. to manufacturer specification Figure 7.4 Possibility 3: Shield grounded in safe area All Rights Reserved. Copyright © 2006, Rota Yokogawa IM 01R01B02-01E-E 5th edition October 01, 2020-00...
  • Page 35: Service

    The DEVICE_REVISION is integrated in the file name of the EDD as number nn, e.g. filename_nn_xx. All Rights Reserved. Copyright © 2006, Rota Yokogawa IM 01R01B02-01E-E 5th edition October 01, 2020 -00...
  • Page 36 Block specific TAG for customer use by ordered scale STRATEGY Strategy Unsigned16 User-specified value e.g. for configu- ration or diagnostics as a sorting key All Rights Reserved. Copyright © 2006, Rota Yokogawa IM 01R01B02-01E-E 5th edition October 01, 2020 -00...
  • Page 37: Appendix 1. List Of Parameters For Each Block Of Ramc

    Allows user specific status control (low nibble) Diagnosis Unsigned8 According to default Allows user specific diagnosis control Mapping: (high nibble) Slot Unsigned8 Not used Index Unsigned8 Not used All Rights Reserved. Copyright © 2006, Rota Yokogawa IM 01R01B02-01E-E 5th edition October 01, 2020-00...
  • Page 38 Electr. Serial No. Unsigned32 E.g.: 7999999 Indicates electronic serial number VIEW_1 n.a. Indicates a Profile defined parameter preselection VIEW_2 n.a. Indicates a Profile defined parameter preselection All Rights Reserved. Copyright © 2006, Rota Yokogawa IM 01R01B02-01E-E 5th edition October 01, 2020 -00...
  • Page 39: A1.2 Al Function Block

    Recipe Operation Phase Batch Phase Unsigned16 Input and indication of active Control Recipe Phase R/W* - Cyclic indication of process variable/ input in manual block mode All Rights Reserved. Copyright © 2006, Rota Yokogawa IM 01R01B02-01E-E 5th edition October 01, 2020-00...
  • Page 40 For future use (not available) Value Upper Warning Float Indicates the value which caused the Output Value warning * Writable in block mode "MAN" only! All Rights Reserved. Copyright © 2006, Rota Yokogawa IM 01R01B02-01E-E 5th edition October 01, 2020 -00...
  • Page 41 OUT parameter (used for units not contained in the code list). VIEW_1 n.a. Indicates a Profile defined parameter preselection VIEW_2 n.a. Indicates a Profile defined parameter preselection All Rights Reserved. Copyright © 2006, Rota Yokogawa IM 01R01B02-01E-E 5th edition October 01, 2020-00...
  • Page 42: A1.3 Transducer Block

    NOMINAL_SIZE_ Nominal Size Unit Unsigned16 Det. by ordered Indicates the unit of the ideal size of the UNITS device measuring pipe All Rights Reserved. Copyright © 2006, Rota Yokogawa IM 01R01B02-01E-E 5th edition October 01, 2020 -00...
  • Page 43 Float Det. by ordered Indicates flow value printed on scale VALUE scale (at 100 %) SOFT_REVISION FW Version OctetString e.g. V1.00 Indicates transmitter's firmware version All Rights Reserved. Copyright © 2006, Rota Yokogawa IM 01R01B02-01E-E 5th edition October 01, 2020-00...
  • Page 44 Electr. Long Tag OctetString Optionally det. by Indicates and changes transmitter's ordered device Long Tag Number (32 characters) VIEW_1 n.a. Indicates a Profile defined parameter preselection All Rights Reserved. Copyright © 2006, Rota Yokogawa IM 01R01B02-01E-E 5th edition October 01, 2020 -00...
  • Page 45 Read/ Initial value Functional Description Index Parameter Structure Write VIEW_5 n.a. Indicates a manufacturer specific parameter preselection VIEW_6 n.a. Indicates a manufacturer specific parameter preselection All Rights Reserved. Copyright © 2006, Rota Yokogawa IM 01R01B02-01E-E 5th edition October 01, 2020-00...
  • Page 46: Appendix 2. Application, Setting And Change Of Basic Parameters

    It is recommended to use this parameter for loop checks and other purposes. Output signal low cut setup Sets the low cut between 5 % to 15 % of VOLUME_FLOW_HI_LIMIT or MASS_FLOW_HI_LIMIT. All Rights Reserved. Copyright © 2006, Rota Yokogawa IM 01R01B02-01E-E 5th edition October 01, 2020 -00...
  • Page 47: A2.2 Setting And Change Of Basic Parameters

    Changed parameters may not be written to the device. Refer to the “List of parameters for each block of the RAMC” for details of the Write Mode for each block. All Rights Reserved. Copyright © 2006, Rota Yokogawa IM 01R01B02-01E-E...
  • Page 48: A2.3 Setting The Ai Function Blocks

    If simulation is enabled, AI block uses SIMULATE_STATUS and SIMULATE_VALUE as the input, and if disabled, the AI block uses the Status and Value of the TB's Process Variable selected by the channel as input. All Rights Reserved. Copyright © 2006, Rota Yokogawa IM 01R01B02-01E-E 5th edition October 01, 2020 -00...
  • Page 49 Rheinstr. 8 D-79664 Wehr Germany For the actual manufacturing location of your device refer to the model code and/or serial number. IM 01R01B02-01E-E 5th edition October 01, 2020-00 All Rights Reserved. Copyright © 2006, Rota Yokogawa Subject to change without notice...

Table of Contents