Operation
Operating Instructions 52Xi, 52Xi-75 - 00.0 - 10/2021
4.3.2
Machine 527i - needle system 134; 134-35
Pic. 3: Needle inserting/replacing
(1) - Needle bar
(2) - Screw
(3) - Needle
1.
Turn the handwheel until the needle bar (1) reaches the upper
end position.
2.
Loosen the screw (2).
3.
Pull the needle (3) out towards bottom.
4.
Insert the new needle 134 according to picture (A).
5.
Unscrew the screw (5) and insert a new needle 134-35
according to picture (B).
Important: Align the needle ins such a way that the scarf (4) faces
the hook.
6.
Tighten the screw (2).
A
①
②
③
④
(4) - Scarf
(5) - Screw
B
⑤
37