g)
From the UPLOAD menu in the terminal program locate and click on the UPLOAD button,
starting the procedure;
h)
A progress bar will appear, showing the state of the upload. It can take 5-10 minutes before
the progress bar is full and the following message is displayed:
i)
After the upload is complete a short beep sound is generated, signaling that the UPLOAD
window can be closed. Press the DISCONNECT button and close the ACOM TERMINAL S
program;
j)
The tuner non-volatile memory and the table ANTENNA ASSIGNMENTS are automatically
restored with tuning settings, antenna types, names, and band coverage from the uploaded
backup file ".bkp" after a successful procedure;
k)
Turn OFF the amplifier and disconnect the serial cable between amplifier and PC.
In the rare case something goes wrong and the procedure fails, close the UPLOAD window
with the CLOSE button. In the ATU SERVICE menu select a different line on the amplifier
screen and then go back to the UPLOAD position. Repeat the procedure as described
above.

6.2.8. Aging and Refreshing of Settings

The TUNING SETTINGS OUTDATED function allows the operator to specify a "period of validity" or "time
period allowed" of the settings retrieved by the "quick tuning" commands from the tuner memory. The hours
are presented as a "total time the tuner was powered".
The limits of the aging alarm can be specified by the operator in four stages: [100 - 300 - 1000 - 3000] hours.
Each setting retrieved from tuner memory comes with the number of hours that the tuner has been in
operation since the time the setting was stored, up to the time it was retrieved. If the time period of the
retrieved setting is older than the limit specified by the operator, the alert text TUNING OUTDATED is
displayed on the amplifier screen, but the outdated tuning settings can still be used.