C
C
O
N
T
R
O
N
T
R
2

Technical data

Specifications
Electrical rating
Power
IP code
Ambient temperature
Weight
Dimensions (L×W×H)
Permeate conductivity ranges
Screw terminal pinout
Live
Neutral
Ground
Conductivity meter
Temperature sensor
Pressure switch before pump
Pressure switch after pump
High permeate pressure switch
Level switch
Stop switch
High pressure pump or magnetic
starter
Alarm signal
Entry valve
Bypass valve
Forward flush valve
O
L
L
E
R
O
L
L
E
R
DESCRIPTION
230 V, 50-60 Hz, 6 A fuse
4 VA
IP 65
5...40 °C
0,25 kg
60×120×250 mm
0...50 μS/cm
0...1000 μS/cm
Power
L
230 V
N
Inputs
cond
+ temp -
P_in
5 V 1 mA
P_max
dry
P_perm
contact
level
(NC/NO)
stop
Outputs
230 V
pump
750 W
alarm
valve_in
230 V
valve_bypass
100 W
valve_rinse
DESIGNATOR
PIN #
35
34
33
1 – white
2 – black
3 – red
4 – green
5 – blue
8-9
10-11
12-13
14-15
6-7
31-32
30 (ground)
28-29
18-17 (NO)
18-19 (NC)
16 (ground)
26-25 (NO)
26-27 (NC)
24 (ground)
22-21 (NO)
22-23 (NC)
20 (ground)
17