BFT U-link LEO B CBB 3 400 W01 Installation Manual page 13

Hide thumbs Also See for U-link LEO B CBB 3 400 W01:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 13
x2
***
0---
10--
ALT
follow the user guide
language
autoset
l. s w adj
LIMIT SWITCH
ADJUSTMENT
Control unit software version
stat
OK
vers
bft . . .
+/-
- +
No total
manoeuvres (in hundreds)
n. cycles
OK
0000
+/-
- +
List of last 30 errors
01.33
OK
err
02.01
........
30.15
+/-
0---
password
ACCESS MENUS Fig. 1
INSTALLATION MANUAL
150-
1520
See PARAMETERS MENU
See LOGIC MENU
Diagnostics
code
START E external start input activated
STRE
START I internal start input activated
STRI
OPEN input activated
OPEN
CLOSE input activated
CLS
PED pedestrian input activated
PED
TIMER input activated
TIME
STOP input activated
STOP
PHOT photocell input activated
PHOT
PHOT OP opening photocell input activated
PHOP
PHOT CL closing photocell input activated
PHCL
BAR safety edge input activated
BAR
SWC motor closing limit switch input activated
SWC
SWO motor opening limit switch input activated
SWO
Mechanical release activated
rls
Photocell test failed
ER01
Safety edge test failed
ER02
Opening photocell test failed
ER03
Closing photocell test failed
ER04
8k2 safety edge test failed
er06
Board hardware test error
ER1x*
Encoder error
ER2x*
Reverse due to obstacle - Amperostop
ER3x*
Thermal cutout
ER4x*
ER70, ER71
Internal system supervision control error.
ER74, ER75
Consistency error of the control unit's parameters (Logics
ER72
and Parameters)
D-track parameter error
ER73
*X= 0, 1, .., 9, A, B, C, D, E, F
10--
150-
*** Password entry.
ok
Request with Protection Level
logic set to 1, 2, 3, 4
35. 4 0
DESCRIPTION
1520
prg
Scroll up
Scroll down
Con rm/Switch on display
Exit Menù
Obstacle threshold
Instantaneous force motor
NOTES
 
 
 
 
 
 
 
 
 
 
 
 
 
Check position of release
Check photocell connection and/or logic settings
Check safety edge connection and/or logic settings
Check photocell connection and/or param-
eter/logic setting
Check photocell connection and/or param-
eter/logic setting
Check safety edge connection and/or
parameter/logic settings
- Check connections to motor
- Hardware problems with board (contact
technical assistance)
- Motor power cables disconnected.
Reverse 2 phases in the supply terminal.
- Actuator movement is too slow or stopped
with respect to programmed operation.
Check for obstacles in path
Allow automated device to cool
Try switching the board off and back on again.
If the problem persists, contact the technical
assistance department.
Pressing OK the detected settings are confir-
med. The board will keep on working with the
detected settings.
The board settings must be checked (Para-
meters and Logics)
Pressing OK, the board will keep on working
with D-track as a default.
An autoset is required
 
LEO B CBB 3 400 W 01-
13

Hide quick links:

Advertisement

Table of Contents
loading