  • Page 1 PROFESSIONAL MEDICAL PRODUCTS ASPIRATORE CHIRURGICO VEGA VEGA SUCTION ASPIRATOR ASPIRATEUR VEGA CHIRURGISCHER ABSAUGER VEGA ASPIRADOR QUIRÚRGICO VEGA APARELHO DE SUCḈÃO CIRÚRGICO VEGA 28210 0476 Gima S.p.A. Via Marconi, 1 - 20060 Gessate (MI) Italy gima@gimaitaly.com - export@gimaitaly.com www.gimaitaly.com Made in Italy...
  • Page 2: Important Safety Rules

    ENGLISH VEGA SURGICAL ASPIRATOR is a medical device powered by 230V ~ 50Hz electricity, to be used for nasal, oral, tracheal aspiration of body fluids, such as mucus, phlegm and blood, in adults or children. Luminaire designed to offer ease of transport and continuous use.
  • Page 3: Technical Characteristics

    CONTRAINDICATIONS - Before using the VEGA, consult the instructions for use: failure to read all the instructions in this manual can be harmful for the patient. - The device cannot be used to drain chest fluids;...
  • Page 4: Cleaning Of The Device

    ENGLISH Working Condition Room temperature: 5 ÷ 35°C Room humidity percentage: 10 ÷ 93% RH Atmospheric pressure: 700 ÷ 1060 hPa Conservation condition and Transport Room temperature: -25 ÷ 70°C Room humidity percentage: 0 ÷ 93% RH Atmospheric pressure: 500 ÷ 1060 hPa The technical specifications may change without notice.
  • Page 5: Cleaning Of Accessories

    ENGLISH Conical fitting: the number of cycles of sterilization and the number of cleaning cycles is strictly linked to the employment of the said component. Therefore, after each cleaning cycle, it is up to the final user to verify whether the fitting is suitable for reuse. The component must be replaced if there are visible signs of decay in the material constituting the said component.
  • Page 6 2° case – If both the security system doesn’t work, there is the possibility that liquid comes inside the device, in this case return the device to GIMA technical service. Gima S.p.A. will provide upon request electric diagrams, components list, descriptions, setting in- structions and any other information that can help the technical assistance staff for product repair.
  • Page 7 ENGLISH INSTRUCTION FOR USE • The device must be checked before each use in order to detect malfunctions and / or damage caused by transport and / or storage. • The working position must be such as to allow one to reach the control panel and to have a good view of the empty indicator, the jar and the antibacterial filter.
  • Page 8 Guidance and manufacturer’s declaration – electromagnetic Emissions The VEGA SUCTION UNIT is intended for use in the electromagnetic environment specified below. The customers or the user of the VEGA SUCTION UNIT should make sure that it’s used in such an environment.
  • Page 9 Guidance and manufacturer’s declaration – Immunity Emissions The VEGA SUCTION UNIT is intended for use in the electromagnetic environment specified below. The customers or the user of the VEGA SUCTION UNIT should make sure that it’s used in such an environment. Immunity Test...
  • Page 10 The VEGA SUCTION UNIT surgical aspirator is intended to operate in an electro-magnetic environment where RF irra- diated interferences are under control. The client or operator of the VEGA SUCTION UNIT device can help prevent elec- tro-magnetic interference by keeping a minimum distance between the portable and mobile RF communication devices (transmitters) and the VEGA SUCTION UNIT device, as recommended below, in relation to the radio-communication maximum output power.
  • Page 11 Disposal: The product must not be disposed of along with other domestic waste. The users must dispose of this equipment by bringing it to a specific recycling point for electric and electronic equipment. GIMA WARRANTY TERMS The Gima 12-month standard B2B warranty applies.