Summary of Contents for Crane PROSSER HYMERGIBLE 7-06000 Series
Page 1
Read all instructions in this manual before operating pump. As a result of Crane Pumps & Systems, Inc., constant product improvement program, product changes may occur. As such Crane Pumps & Systems reserves the right to change product without prior written notifi cation.
Other brand and product names are trademarks or registered trademarks of their respective holders. HYMERGIBLE® is a registered trademark of Crane Pumps & Systems, Inc. ® PROSSER is a registered trademark of Crane Pumps & Systems, Inc 1996, 1997, 1998, 2002, 2/06, 9/06...
WARNING! Operation against a closed discharge valve will cause premature bearing IMPORTANT! - Crane Pumps & Systems, Inc. is not and seal failure on any pump, and on end responsible for losses, injury, or death resulting from a...
For the location of the nearest Prosser Service Center, check hydraulic fl uid line. Use fi lter elements rated at 25 micron your Prosser representative or Crane Pumps & Systems, Inc., absolute. Protect hydraulic hoses from cuts and abrasion. Service Department in Piqua, Ohio, telephone (937) 778-8947 ALWAYS USE A BACK-UP WRENCH WHEN CONNECTING or Crane Pumps &...
3.) Fastenings: All bolts, nuts, screws and other means of Return one copy to the Crane Pumps & Systems, Inc. Service fastenings and also threaded covers, shall be in place, properly Department and store the second with the pump manual.
SECTION F: SERVICE AND REPAIR NOTE: All item numbers in ( ) refer to Figures 7 & 8 and 9 & 10 For 2 Stage Models. WARNING ! - Hydraulic power to the pump must be disconnected to prevent personnel danger before any service work is done to the pump.
Page 9
F-2.2) Reassembly: Inspect strainer (24) and clean, making sure hole are not To reassemble, insert key (15) into shaft (39), slide shims clogged to ensure unrestricted fl ow. Now position strainer (17a), (17b) & (17c) onto shaft, then apply an anti-seize (24) onto suction case (4).
Page 10
When installed correctly, there will be movement upward in shaft assembly. This is opposite of downward thrust which occurs when pump is running. “LOOSENESS” between inner and outer race is normal for angular contact bearing. Bearing failure will result in a short period of time if it is not installed as specifi...
The three recessed head cap screws (33) can now be SECTION: G REPLACEMENT PARTS removed from the motor mounting plate (34). Remove the mounting plate (34), hydraulic motor (6) and retainer (23). If G-1 ORDERING REPLACEMENT PARTS: motor (6) is being replaced, remove mounting plate (34) by Your local Prosser distributor can supply parts and repair removing screws (35).
TROUBLE SHOOTING CAUTION ! Always disconnect the pump from the electrical power source before handling. If the system fails to operate properly, carefully read instructions and perform maintenance recommendations. If operating problems persist, the following chart may be of assistance in identifying and correcting them: MATCH “CAUSE”...
Crane Pumps & Systems, Inc. Distributor. RETURNED GOODS RETURN OF MERCHANDISE REQUIRES A “RETURNED GOODS AUTHORIZATION”. CONTACT YOUR LOCAL CRANE PUMPS & SYSTEMS, INC. DISTRIBUTOR. Products Returned Must Be Cleaned, Sanitized, Or Decontaminated As Necessary Prior To Shipment, To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material.
Need help?
Do you have a question about the PROSSER HYMERGIBLE 7-06000 Series and is the answer not in the manual?
Questions and answers