Preparation - Lenze g500-S Series Mounting And Switch-On Instructions

Ie2, ie3 shaft-mounted helical geared motor version b
Hide thumbs Also See for g500-S Series:
Table of Contents

Advertisement

Preparation

Protect shaft sealing rings from contact with solvents.
Remove protection covers from shafts.
Thoroughly remove anticorrosion agents from the shaft and from flange faces.
Draw the transmission elements onto the output shaft only by using the centering thread.
Align the output shaft and transmission elements exactly to avoid tensions.
Mount belt pulleys, sprockets, or gear wheels as close as possible to the shaft shoulder in
order to keep the bending load of the shaft and the bearing forces at a minimum level.
Tighten all screw connections with the specified torques and secure them with standard
screw locking adhesive.
Check paint for damage and repair professionally.
Thread
M3
Strength
4.8
Nm
0.7
8.8
Nm
1.3
10.9
Nm
1.9
M4
M5
M6
M8
Tightening torque Nm ±10 %
1.4
2.8
4.8
12
3.0
5.9
10.1
24.6
4.6
8.6
14.9
36.1
Mechanical installation
M10
M12
M16
M20
23
48
84
206
415
71
123
302
592
Preparation
M24
M27
M30
714
1050
1428
1017
1496
2033
21