Commissioning

Important notes

Temperature ranges
The following temperature ranges are available matched to your ambient conditions:
Default
Deep-freeze
Wide range
Check the ambient temperature and lubricant shown on the nameplate.
4Nameplates
Pay attention to the notes on the temperature ranges!
Temperature ranges
Standard
Ambient temperature
Lubricant
Note
Low-temperature
Ambient temperature
Lubricant
Note
Wide range
Ambient temperature
Lubricant
Note
^ 12
0 °C ... +40 °C
Mineral oil
• CLP 460
Synthetic oil
• CLP HC 220
Food-compatible oil
• CLP HC 220 USDA H1
At an ambient temperature generally over +30 °C:
• The application case must be checked by Lenze.
-30 °C ... +10 °C
Food-compatible oil
• CLP HC 46 USDA H1
When starting a cold motor at below -20 °C, increased starting torques are to be expected due to the higher
viscosity of the roller bearing grease.
• During project planning, allow a motor starting torque reserve of about 20%.
Commissioning at over +10 °C:
• Operate the drive at max. 50% of the rated torque to avoid a reduction in service life.
-30 °C ... +40 °C
Synthetic oil
• CLP HC 220
When starting a cold motor at below -20 °C, increased starting torques are to be expected due to the higher
viscosity of the roller bearing grease.
• During project planning, allow a motor starting torque reserve of about 30%.
At an ambient temperature generally over +30 °C:
• The application case must be checked by Lenze.
At a constant temperature between -30 °C and -25 °C, the service life is up to 20% lower than with the low-
temperature range.