Connection Via Han Connector - Lenze g500-S Series Mounting And Switch-On Instructions

Ie2, ie3 shaft-mounted helical geared motor version b
Hide thumbs Also See for g500-S Series:
Table of Contents

Advertisement

Connection via HAN connector

The power, brake and temperature monitoring can be connected in the HAN connector.
The designs HAN 10E or HAN modular with two power modules (16 A or 40 A) are available.
The HAN 10E connector is only available for motors with the connection method
Y/Δ.
An additional rectifier can be connected with HAN modular.
Position of the connections
Note
Meaning
1
Power connection
Brake connection
PE connection
Connection of temperature monitoring
Additionally for HAN-Modular:
• Rectifier connection
HAN 10E connector
The motor connection is specified in the counter plug.
The connector is only suitable for motors with the connection method Y/Δ.
Bridge arrangement in the mating connector HAN 10E
Contact
Name
6-7-8
y
1-6
Δ
2-7
3-8
HAN 10E pin assignment
Contact
1
U1
2
V1
3
W1
4
+/AC
5
-/AC
6
W2
7
U2
8
V2
9
TCO/+PT1000
10
TCO/-PT1000
HAN modular connector
The motor connection is specified in the terminal box.
1
Meaning
Circuit
Meaning
Motor winding phase
Brake
Motor winding phase
Temperature monitoring
Electrical installation
Motor connection
Connection via HAN connector
Illustration
6
7
8
9 10
1
2
3
4
5
45