FabiaTech Corporation
COM Port 1/2 Select Function
These fields item can select RS-232, RS-422 and RS-485 of select port 1/2.
Available Options: RS-232, RS-422 and RS485
Default setting: RS-232
Serial Port C/D
This item allows users to enable and disable Serial Port C/D (COM3/4). If set to Auto,
is EFI/OS chooses configuration.
Available Options: Disabled, Enabled and Auto
Default setting: Auto
Base I/O Address C/D
These fields item can select serial port address I/O, When Serial Port C/D set to
Enabled for User configuration.
Available Options: 3E8, and 2E8
Default setting: 3E8 (Port -C)/2E8 (Port-D)
INTERRUPT C/D
These fields item can select serial port interrupt, When Serial Port C/D set to
Enabled for User configuration.
Available Options: IRQ5, and IRQ7
Default setting: IRQ5 (Port -C)/ IRQ7 (Port-D)