LOGICDATA DYNAMIC MOTION System Manual page 30

System
Hide thumbs Also See for DYNAMIC MOTION:
Table of Contents

Advertisement

12
Power Stage Overcurrent
13
DC Under Voltage
14
Critical DC Over Voltage
15
Strain Gauge is defective
17
Error during pairing sequence
18
Parameterization or firmware of
different Actuators in the Table
System are incompatible.
19
Too many / too few Actuators
connected
20
Motor short circuit and/or open
load
21
Firmware Error
22
Power Hub overload
23
Motor Under Voltage
Do not operate the DYNAMIC MOTION system if problems persist. Contact LOGICDATA
NOTICE
for further information.
DYNAMIC MOTION SYSTEM - SYSTEM MANUAL // PAGE 30
Release all Keys and wait for 5 seconds. Then, try again.
Release all Keys and wait for 5 seconds. Then, try again.
Release all Keys and wait for 5 seconds. Then, try again.
Release all Keys and wait for 5 seconds. Then, try again.
Contact LOGICDATA if the problem persists. Do not
operate the DM System if components are broken.
Disconnect the Power Hub from the Mains. Then, dis-
connect System from the Power Hub. Reconnect the
system again, then operate the DM System as normal.
If this fails, perform a factory reset (see DM System
Manual).
Re-paramaterize the Actuators. Contact LOGICDATA for
further information.
Connect the correct number of Actuators (as specified in
setup).
Contact LOGICDATA.
Disconnect the Power Hub from the Mains. Then, dis-
connect System from the Power Hub. Reconnect the
system again, then operate the DM System as normal.
Release all Keys and wait for 5 seconds. Then, try again.
Release all Keys and wait for 5 seconds. Then, try again.