15. POSITION OF THE LOOPER THREAD TAKE-UP

Lower the needle from the highest position and adjust, so that the thread comes off from the highest point of the looper Thre-
ad Take-up (I) when left needle reaches to the middle part of the looper .
The adjustment is made by loosening screw (j) (Fig. 18 & 19)

16. ADJUSTMENT OF THE LOOPER *

Please refer to the below table and Fig. 20.
* Only for Treccia (flat bed)

17. HEIGHT OF THE NEEDLES

When the tip of lLooper comes to the center of the left needle, Looper must
pass 0,5~1,0 mm above the upper end of eye—that is—the height of needle is
set on the basis of Looper. Both—needles and looper should be properly fixed.