OPERATING INSTRUCTIONS
LEAK TEST
1. Make 2-3 oz. of leak test solution
detergent and three parts water).
2. Apply several drops of solution
where hose attaches to regulator.
3. Apply several drops of solution
where regulator connects to cylinder.
4. Make sure all patio heater valves are OFF.
5. Turn cylinder valve ON.
IF BUBBLES APPEAR AT ANY CONNECTION, THERE IS A LEAK.
Turn cylinder valve OFF.
If leak is detected at hose/regulator connection, tighten connection and
perform another leak test. If bubbles continue to appear, c
ervice.
If leak is detected at regulator/cylinder valve connection, disconnect,
reconnect, and perform another leak test. If you continue to see bubbles
after several attempts, cylinder valve is defective. C
ervice
IF NO BUBBLES APPEAR AT ANY CONNECTION, THE CONNECTIONS ARE SECURE.
Note: Whenever gas connections are loosened or removed, you must
perform a complete leak test.
WARNING:
FOR OUTDOOR USE ONLY
CARBON MONOXIDE HAZARD
This appliance can produce carbon monoxide
which has no odor. Using it in an enclosed
space can kill you. Never use this appliance
in an enclosed space such as a camper, tent
or home.
Contact us for assistance: (866) 985-7877 |
WARNING
Perform all leak tests outdoors.
NEVER leak test when smoking
Do not use heater until all connections
have been leak tested and show no signs
of leakage.
ustomer
ustomer
Caution: Do not attempt to
operate this appliance until you
have read and understand all
Safety Information in this manual
and all assembly is complete and
leak tests have been performed.
BEFORE TURNING GAS SUPPLY ON:
1. Your heater was designed and
approved for OUTDOOR use
only. Do NOT use it inside a
building, garage, or any other
enclosed area.
2. Make sure surrounding areas are
free of combustible materials,
3. Ensure that there is no
obstruction to air ventilation. Be
sure all gas connections are tight
and there are no leaks.
4. Be sure the cylinder cover is
clear of debris. Be sure any
component removed during
assembly or servicing is
replaced and fastened prior
to starting.
BEFORE LIGHTING:
1. Heater should be thoroughly
inspected before each use, and
at least annually. If re-lighting a
hot heater, always wait at least
5 minutes.
2. Inspect the hose assembly for
evidence of excessive abrasion,
cuts, or wear. Suspected areas
should be leak tested. If the
hose leaks, it must be replaced
prior to operation. Only use the
replacement hose assembly
10