Operation

8.10 Switching on again after an emergency switching-off

8.8

Draining the coolant

If you take the machine out of service, drain the coolant if this is necessary for the ambient
conditions.
Type of construction IM B3
Use the coolant drain hole
Other types of construction
In other types of construction, you must blow the coolant out with compressed air.
8.9

Re-commissioning the machine

When you re-commission the machine, proceed as follows:
● Study the record made when the machine was decommissioned, and reverse the measures
● Perform the measures listed in the "Commissioning" section.
See also
Start-up (Page 97)
8.10
Switching on again after an emergency switching-off
● Check the machine before recommissioning the driven machine after an Emergency Off.
● Eliminate all the causes that have led to the emergency off
116
Coolant connections
Coolant drain hole
that were taken for conservation and storage.
in the bearing shield to drain the coolant.
SIMOTICS FD 1LH1
Operating Instructions 04/2016