Selecting The Motor Type And Motor Data In The Starter Program - Siemens SIMOTICS FD 1LH1 Operating Instructions & Installation Instructions

Induction motor
Hide thumbs Also See for SIMOTICS FD 1LH1:
Table of Contents

Advertisement

Start-up
7.9 Setting the motor parameters at the converter
7.9.1

Selecting the motor type and motor data in the STARTER program

Prerequisites
● The motor is connected to the converter and is ready for operation.
● The converter must have at least software version 4.6.
● You have installed the STARTER software with at least version 4.3.1 with SSP, and you
● The STARTER program has been started. You are in the "Configuration" dialog screen
Selecting motor parameters
1. Enter a name for the motor in the "Motor name" input field.
2. Select the "Enter motor data" option.
104
are connected to the converter. You require SSP V4.6 for the SINAMICS G120P inverter.
form.
Subsequent motor assignment is simplified by selecting a unique name.
SIMOTICS FD 1LH1
Operating Instructions 04/2016

Advertisement

Table of Contents
loading

Table of Contents