3.4.27
UnsubscribeForAlarms
UnsubscribeForAlarms(alarmChannel : string) : void
Parameters
● alarmChannel
Return value(s)
None.
Exceptions
RfReaderApiException
Note
This function unregisters for asynchronous notifications of RFID alarms. Users have to either
specify the name of the alarm channel (which depends on the underlying configuration) or
use an empty string or "ALL" in order to subscribe to all available alarm.
Limitations
RF-MANAGER mode only.
If there is no configuration data available or the contained alarm channels do not match in
name, calls to UnsubscribeForAlarms will fail.
Version information
Supported in RFID Reader Interface: since V1.1
Mobile Readers
Function Manual, 12/2010, J31069-D0198-U001-A2-7618
The name of an alarms channel that you want to unsubscribe
Error while communicating with the reader service.
Check the Error member for more information.
RFID Reader Interface Reference
3.4 IRfReaderApi
71