RFID Reader Interface Reference
3.4 IRfReaderApi
Parameters
● currentTagID
● newTagID
● Password
Return value(s)
None
Exceptions
RfReaderApiException
Note
This method writes a new tag ID to an existing tag.
A valid tag ID must be specified for a tag currently within the field before you can write a new
ID, or if no tag ID is specified, the first tag within the field will be written.
All tag IDs are given in a plain hexadecimal encoded string (i.e., each byte is represented by
a two-letter hexadecimal number).
When writing an EPC class1 Gen2 tag, the password is verified for access rights.
No passwords are required for writing an ISO tag. Please provide an empty string.
RF300 device does not support writing of Tag iDs at all
Version information
Supported in RFID Reader Interface: since V1.0
52
The ID of a tag to be written to given as a hexadecimal encoded string (i.e., each byte is
represented by a two-letter hexadecimal number).
The new ID to be written given as a hexadecimal encoded string (i.e., each byte is
represented by a two-letter hexadecimal number).
An access password if needed. If none needed use an empty string. A password is a
hexadecimal encoded string of up to eight characters.
Error while communicating with the reader service.
Check the Error member for more information.
Function Manual, 12/2010, J31069-D0198-U001-A2-7618