Getantennapower; Setcommunicationscheme - Siemens SIMATIC RF310M Function Manual

Mobile readers
Hide thumbs Also See for SIMATIC RF310M:
Table of Contents

Advertisement

RFID Reader Interface Reference
3.4 IRfReaderApi
Note
The handheld devices have limited settings for the antenna power:
Valid ranges for the RF680M are: 10, 25, 50, 100, 200, 300, 400 and 500 mW;
Due to physical limitations, the device could also not set exactly the requested value, but
choose the nearest possible value. So you could try to set the antenna power to 100mW but
the device may return only 98mW.
Version information
Supported in RFID Reader Interface since V1.3
3.4.8

GetAntennaPower

GetAntennaPower( ) : uint
Parameters
None
Return value(s)
This functions returns the current antanna power.
Exceptions
RfReaderApiException
Note
The handheld devices have limited settings for the antenna power:
Valid ranges for the RF680M are: 10, 25, 50, 100, 200, 300, 400 and 500 mW;
Due to physical limitations, the device could also not set exactly the requested value, but
choose the nearest possible value. So you could try to set the antenna power to 100mW but
the device may return only 98mW.
Version information
Supported in RFID Reader Interface since V1.3
3.4.9

SetCommunicationScheme

SetCommunicationScheme (communicationScheme: uint) : void
48
Error while starting the communication with the reader. Check
the Error member for more information.
Function Manual, 12/2010, J31069-D0198-U001-A2-7618
Mobile Readers

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic rf610mSimatic rf680m

Table of Contents