RFID Reader Interface Reference
3.4 IRfReaderApi
Note
The handheld devices have limited settings for the antenna power:
Valid ranges for the RF680M are: 10, 25, 50, 100, 200, 300, 400 and 500 mW;
Due to physical limitations, the device could also not set exactly the requested value, but
choose the nearest possible value. So you could try to set the antenna power to 100mW but
the device may return only 98mW.
Version information
Supported in RFID Reader Interface since V1.3
3.4.8
GetAntennaPower
GetAntennaPower( ) : uint
Parameters
None
Return value(s)
This functions returns the current antanna power.
Exceptions
RfReaderApiException
Note
The handheld devices have limited settings for the antenna power:
Valid ranges for the RF680M are: 10, 25, 50, 100, 200, 300, 400 and 500 mW;
Due to physical limitations, the device could also not set exactly the requested value, but
choose the nearest possible value. So you could try to set the antenna power to 100mW but
the device may return only 98mW.
Version information
Supported in RFID Reader Interface since V1.3
3.4.9
SetCommunicationScheme
SetCommunicationScheme (communicationScheme: uint) : void
48
Error while starting the communication with the reader. Check
the Error member for more information.
Function Manual, 12/2010, J31069-D0198-U001-A2-7618