Daikin 2MXS18GVJU Service Manual page 19

Removal procedure, 7.1/8.0 kw class, 18000 btu/h class, outdoor unit, inverter, multi type, heat pump
Hide thumbs Also See for 2MXS18GVJU:
Table of Contents

Advertisement

Si12-994
Step
5
Lift up the main PCB.
Disconnect the
6
connectors [S31] [S32]
[S33] [S71] [H1] [H2].
The figure shows the
7
main PCB.
Removal Procedure
Procedure
[S31]
[S71]
[S33]
[S32]
[S93]
[S92]
[S80]
[S21] [S20] [S40]
(R2181)
(R10362)
[H1] (yellow)
[H2] (blue)
(R10363)
FU2 (3.15A)
[S90]
[H1]
Removal of PCBs (Pattern 2)
Points
[H2]
[S32]
[S33]
[S71]
[S31]
(R10356)