Daikin 2MXS18GVJU Service Manual page 15

Removal procedure, 7.1/8.0 kw class, 18000 btu/h class, outdoor unit, inverter, multi type, heat pump
Hide thumbs Also See for 2MXS18GVJU:
Table of Contents

Advertisement

Si12-994
Step
5
Remove the drip proof
plate.
Disconnect the
6
connectors [S52]
[S102] from the service
monitor PCB.
The figure shows the
7
service monitor PCB.
Release the 2 hooks to
8
remove the service
monitor PCB.
Removal Procedure
Procedure
Drip proof plate
Service
monitor PCB
[S52]
[S102]
LED A
LED 1
LED 2
LED 3
LED 4
Hook
Hook
(R6577)
(R6578)
Priority room setting switch
(SW4)
Wiring error check switch
(SW3)
Forced operation ON / OFF
switch (SW1)
NIGHT QUIET mode setting
switch (SW5)
Operation mode switch
(SW2)
(R3064)
(R6579)
Removal of PCBs (Pattern 1)
Points
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

3mxs80ev2cPmxs3gv2c