TURBO XE ATOMIZER
USER'S MANUAL AND OPERATING INSTRUCTIONS
MODEL:
XE-2000-EXP
XE
Rear-Feed
UL and CSA Electrical Components
OPERATOR'S MANUAL
NOTICE
Read & Understand
Retain for Future Reference

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Turbo XE and is the answer not in the manual?

Questions and answers

Summary of Contents for Aquafog Turbo XE

  • Page 1 TURBO XE ATOMIZER USER'S MANUAL AND OPERATING INSTRUCTIONS MODEL: XE-2000-EXP Rear-Feed UL and CSA Electrical Components OPERATOR'S MANUAL NOTICE Read & Understand Retain for Future Reference...
  • Page 2: Table Of Contents

    15 - 16 POTENTIALLY HAZARDOUS SITUATION WHICH, IF NOT AVOIDED, COULD RESULT IN Turbo XE Exploded View ... . 17 - 18 DEATH OR SERIOUS INJURY. Flowmeter Exploded View ....
  • Page 3: General Safety

    OF CONTROL PROGRAMMING. the work area. NEVER OPERATE UNIT WITHOUT WARNING 7. Use of an extension cord for the Turbo XE is THE HOUSING INSTALLED. not recommended. If necessary, consult a certified electrician about use of a heavy- 12. When Turbo XE-EXP are gauge, grounded extension cord.
  • Page 4: Preparation

    reparation ardware HeCklist ools equired (2) 1/4-20" SST U-bolt ► Level ► 7/16" wrenches (4) 1/4" flat washer, lock washer, nut (4) 1/4-20 nylon stop nut SST ► 1/2" wrenches ► 3/32" allen wrench (4) 5/16-18 bolt, flat washer, lockwasher, nut (6) wire tie ►...
  • Page 5: Placement

    lacement Placement Guidelines LOCATE A LEVEL AREA TO SET UP A STAND. TO HANG THE NOTICE UNIT, SECURE AND LEVEL 1" PIPE ABLE TO SUPPORT 80 LBS. Mount the fan high overhead. Allow room in front of and below the fan for the unobstructed propulsion of fog.
  • Page 6 lacement cont Large structures, Natural ventilation In large structures with natural ventilation, propel fog the length of the structure with the first fan row no more than 30' from the end wall. The first fan should > > > > - centered along the end wall (or) - placed no more than 30' from the side wall, with additional fans in the row equally spaced no...
  • Page 7: Installation

    USING A LADDER TO HANG THE TURBO XE IS DANGEROUS. DANGER USE PROPER LIFTING EQUIPMENT LIKE A SCISSOR LIFT. NOTE: THIS UNIT IS SPECIFICALLY DESIGNED ONLY TO BE HUNG WITH IT'S MOTOR IN THE UPRIGHT POSITION. Attach Framework Assembly Securing To Pipe - Use U-bolts provided.
  • Page 8: Motor & Tubing

    & W nstallinG otor ater ubinG Install Motor Slide the motor onto the motor support plate of the framework assembly (as 10-2002 shown in Fig. 3). Secure the base of the motor to the motor support plate using 5/16" hardware provided (Part #56, 57, 58, 116) four each.
  • Page 9: Installing Blade Assembly

    nstallinG laDe ssembly Set Screw Flush to end of shaft Feed Tube Blade Assembly Fig. 5 Blade Assembly Install Blade Assembly Line up the key way and slide the Blade Assembly onto the motor shaft until flush to the end of shaft. NOTE: Make sure the Feed Tube has clearance and does not touch while it enters the reserivor in back of the Blade Assembly.
  • Page 10: Housing & Pivot Adjustment

    & p ousinG ttacHment ivot Venturi Attaching Housing Fig. 7 Locate the six cap screws set aside during preparation. (Refer to Fig. 1) Reposition the housing over the venturi starting with the lower half of the housing. Tilt housing downward to clear the lower lip of U S A the venturi.
  • Page 11: Connecting Water & Power

    GROUND FAULT RECEPTACLE(S) IS RECOMMENDED AND MAY WARNING BE REQUIRED BY LOCAL AND/OR NATIONAL CODE. NOTE: Turbo XE motors are dual voltage and can operate either on high or low PROPERLY voltage. For connection changes, refer to the electrical schematic located on...
  • Page 12 ssembly etail Fig. 10 Connect and seal joints using threaded conduit to a hazardous duty On/Off power supply Use flexible hazardous duty power cord (Available separately: Part #STO-14/3 and # STO-14/4) with a hazardous duty NEMA 5-20 male plug (Available separately: Part #449) ▼...
  • Page 13: Operation

    CLEAR! MAKE SURE GUARDS ARE INSTALLED OR UNIT IS OUT OF REACH. BUMP START Turbo XE and check for proper fan blade rotation (clockwise if looking at front of unit). If incorrect, find rotation connection changes on the motor's electrical schematic.
  • Page 14: Common Setups

    Flowmeter Panel. Head Pressurized Water Supply Height Submersible pump and 1/4 Turn Valve (not included) connects and 1/4 Turn feeds the Turbo XE at a low rate Ball Valve Flowmeter (about 3 GPH) suitable for fumigation. Panel Chemical Feeder Pre-mixed solution...
  • Page 15: Troubleshooting

    roublesHootinG BEFORE INSPECTION AND /OR SERVICE, WARNING DISCONNECT AND LOCK OUT POWER SOURCE. 1. Fan Does Not Operate A.) Check voltage requirements on unit and electrical supply. Check for live receptacle, plug, power line and toggle switch. B.) Look for any loose connections inside the main motor's junction box. 2.
  • Page 16 roublesHootinG cont BEFORE INSPECTION AND /OR SERVICE, WARNING DISCONNECT AND LOCK OUT POWER SOURCE. 6. Fan Motor Becomes Excessively Hot The main fan motor normally becomes very hot to the touch. However, if it gets so hot that it begins to smell or smoke or the power cord becomes hot, discontinue operation and consult an electrician to properly evaluate the problem.
  • Page 17: Turbo Xe Exploded View

    Xe e urbo XploDeD A Q U A F O G...
  • Page 18 659, 32 n g e p t i o 658, 42, 660 Hanger U-Bolts R e a r o f Bolt u s i 400-047 10-2002 o t o o f m i e w S i d t o r ' s J u n c t i o n...
  • Page 19: Flowmeter Exploded View

    loWmeter anel XploDeD COMPONENTS entire panel is also available, part# XE-FP (must specify flowmeter size)
  • Page 20: Part Identification List

    Dentification ID # Description Qty per Unit ID # Description Qty per Unit XE-EXP COMPONENTS FLOWMETER COMPONENTS Housing Safety guard 1/8" NPT street elbow Liquid feed tube fitting Drain fitting 1/8" M x 1/4" F NPT elbow 10-2002 Explosion-Proof motor 115V 1/4"...
  • Page 21: Maintenance

    A. Next, pull the retainer 5. Storage cap straight up by using Protect your Aquafog from winter damage. slot B. NOTE: After cap Expansion due to freezing can burst fittings, is removed, be careful not solenoids and flowmeters.
  • Page 22: Warranty

    Aquafog and accessories are warranted to the original purchaser against defects in material and workmanship under normal use for one full year from date of purchase. Any part determined to be defective and returned to the manufacturer, shipping cost prepaid, will be repaired or replaced at Jaybird Manufacturing, Inc.'s discretion without charge.

This manual is also suitable for:

Xe-2000-exp