  • Page 1 XE MOBILE ATOMIZER USER'S MANUAL AND OPERATING INSTRUCTIONS XE ORSM MODEL  115V 60Hz 1Ph  240V 50Hz 1Ph Rear-Feed UL and CSA Electrical Components OPERATOR'S MANUAL NOTICE Read & Understand Retain for Future Reference...
  • Page 2: Safety Guidelines

    Troubleshooting ....7 - 8 DEATH OR SERIOUS INJURY. Aquafog Fan Exploded View ..9 - 10 WARNING INDICATES A WARNING ORSM Tank Exploded View .
  • Page 3: General Safety

    eneral afety DANGER Since the mobile ORSM uses high-speed HIGH-SPEED ROTATION components to atomize liquids, the following safety precautions must be observed at all times: KEEP SAFETY GUARDS ATTACHED DANGER AND IN GOOD WORKING CONDITION 1. Read all manuals included with this product.
  • Page 4: Unit Preparation

    ettinG tarteD npacking hecklist lectrical DO NOT OPERATE UNIT IF GROUND FAULT RECEPTACLES WARNING WARNING DAMAGED DURING SHIPPING, ARE RECOMMENDED AND MAY HANDLING OR USE. DAMAGE MAY RESULT IN BREAKAGE BE REQUIRED BY LOCAL AND/OR NATIONAL CODE. AND CAUSE INJURY OR PROPERTY DAMAGE. USE OF AN EXTENSION CORD IS NOTICE ►...
  • Page 5: C Ontrols / I Nstallation

    valuation ontrols nstallation BEFORE TESTING FAN MAKE SURE ALL OBJECTS ARE OUT OF THE DANGER ROTATION PATH OF THE FAN BLADES.HIGH-SPEED WARNING. KEEP HANDS CLEAR! MAKE SURE GUARDS ARE INSTALLED OR UNIT IS OUT OF REACH. ► For first-time evaluation, fill tank (with water only) about quarter full. ►...
  • Page 6: Flow Rates

    ates LOW FLOW, Feed Tube HIGH FLOW, Feed Tube Output Range: Output Range: @ 60Hz .75 - 3.75 @ 60Hz 3.0 - 11.25 Colored Insert @ 50Hz 2.8 - 14.0 @ 50Hz 7.6 - 31.2 High Flow Tube (provided) Low Flow Tube (factory installed) To install the high flow tube, first disconnect power.
  • Page 7: Troubleshooting

    roubleshootinG BEFORE INSPECTION AND/OR SERVICE, WARNING DISCONNECT AND LOCK OUT POWER SOURCE. 1. Poor/Inconsistent Fogging Output A.) Inconsistent or spotty chemical coverage usually occurs because the fog volume output is too high. Ideally, fog will disappear when fogging at rates near 3 GPH. To check for fog volume output, refer to Maximum Pre-set Flow Rate (See Page 6).
  • Page 8: T Roubleshooting ( Cont .)

    roubleshootinG cont BEFORE INSPECTION AND /OR SERVICE, WARNING DISCONNECT AND LOCK OUT POWER SOURCE. 5. No Fog A.) The self-priming system will usually take about 10 seconds before you see fog output. Check to see if the flow control valve is open. The valve is open when the handle is down. B.) Check the pre-set flow rate valve located inside the tank (refer to page 6 Factory Pre- set Flow Valve).
  • Page 9: A Quafog F An E Xploded V Iew

    quafoG xploDeD Dentification ID # Description Qty/Unit Housing Safety guard Liquid feed tube fitting Drain fitting 10-2000 WDD motor 115/240V // 60/50Hz Pinned venturi assembly Rear guard 1/4" Heavy large diameter washer 1/4-20 nylon stop nut SST SST washer for feed tube fitting 10-24 x 3/8"...
  • Page 10 600-R 600-L R e a r o f u s i f t o l a t e S i d o t p p i v 400-047 10-2000 t o r ' s J u n c t i o n B o x W-14 10-2000...
  • Page 11 orsM t xploDeD 143 - 3/8" tube fitting provided for optional connection to metering pump k ' s T a n T a n i d e I n s W-14...
  • Page 12 Dentification Dentification ID # Description Qty/Unit 1/4-20 nylon stop nut SST Liquid-tight cord fitting M20 Serrated lock washer SST Fluid level gauge RSM tank Fill cap 1/2" flat washer SST 5/32 x 1 1/4" cotter pin SST Inline strainer 1/4" female NPT T a n 1/4"...
  • Page 13: Maintenance

    5. Storage Protect your mobile Aquafog from winter damage. Expansion due to freezing can burst the fittings or the internal feed pump. If storing unit in below freezing temperatures, be sure all fluid is drained from the tank area. Damage due to freezing is not covered under warranty.
  • Page 14: Warranty

    Aquafog and accessories are warranted to the original purchaser against defects in material and workmanship under normal use for one full year from date of purchase. Any part determined to be defective and returned to the manufacturer, shipping cost prepaid, will be repaired or replaced at Jaybird Manufacturing, Inc.'s discretion without charge.