Troubleshooting ....7 - 8 DEATH OR SERIOUS INJURY. Aquafog Fan Exploded View ..9 - 10 WARNING INDICATES A WARNING HRSM Tank Exploded View .
Page 3
eneral afety Since the mobile HRSM uses high-speed components to atomize liquids, the following safety DANGER HIGH-SPEED ROTATION precautions must be observed at all times: 1. Read all manuals included A motionless atomizer may with this product. Be familiar appear safe, but its blade with the product and controls.
ettinG tarted npacking hecklist lectrical DO NOT OPERATE UNIT IF GROUND FAULT RECEPTACLES WARNING WARNING DAMAGED DURING SHIPPING, ARE RECOMMENDED AND MAY HANDLING OR USE. DAMAGE MAY RESULT IN BREAKAGE BE REQUIRED BY LOCAL AND/OR NATIONAL CODE. AND CAUSE INJURY OR PROPERTY DAMAGE. USE OF AN EXTENSION CORD IS NOTICE ►...
peration Fig. 2 Operation Controls The volume of fog can be regulated by adjusting the Flow Control Valve. (See Fig. 2) Particle size is smaller/drier at lower outputs, so it is Flow Control wise to operate the unit at a lower output for longer Valve periods of time rather than high outputs for short periods of time.
Page 6
eStinG and valuation BEFORE TESTING FAN MAKE SURE ALL OBJECTS ARE OUT DANGER OF THE ROTATION PATH OF THE FAN BLADES.HIGH-SPEED WARNING. KEEP HANDS CLEAR! MAKE SURE GUARDS ARE INSTALLED OR UNIT IS OUT OF REACH. ► For first-time evaluation, fill tank (with water only) about one quarter full. ►...
roubleShootinG BEFORE INSPECTION AND /OR SERVICE WARNING DISCONNECT AND LOCK OUT POWER SOURCE. 1. Fan Does Not Operate A.) Check voltage requirements on unit and electrical supply. Check for live receptacle, plug, power line and toggle switch. B.) Look for any loose connections inside the main motor's junction box. 2.
roubleShootinG Cont BEFORE INSPECTION AND /OR SERVICE WARNING DISCONNECT AND LOCK OUT POWER SOURCE. 6. Poor Quality Fog A.) The liquid feed tube (Part #575) may not be properly positioned. The feed tube is located behind the blade assembly and should be inserted approximately 1/4" into the slot between the motor shaft and the stainless steel face plate.
5. Storage Protect your mobile Aquafog from winter damage. Expansion due to freezing can burst the fittings or the internal feed pump. If storing unit in below freezing temperatures, be sure all fluid is drained from the tank area. Damage due to freezing is not covered...
Aquafog and accessories are warranted to the original purchaser against defects in material and workmanship under normal use for one full year from date of purchase. Any part determined to be defective and returned to the manufacturer, shipping cost prepaid, will be repaired or replaced at Jaybird Manufacturing, Inc.'s discretion without charge.
Need help?
Do you have a question about the HRSM-2000 and is the answer not in the manual?
Questions and answers