  • Page 1 XE MOBILE ATOMIZER USER'S MANUAL AND OPERATING INSTRUCTIONS XE HRSM MODEL  HRSM-2000  HRSM-1500 Rear-Feed UL and CSA Electrical Components OPERATOR'S MANUAL NOTICE Read & Understand Retain for Future Reference...
  • Page 2: Safety Guidelines

    Troubleshooting ....7 - 8 DEATH OR SERIOUS INJURY. Aquafog Fan Exploded View ..9 - 10 WARNING INDICATES A WARNING HRSM Tank Exploded View .
  • Page 3 eneral afety Since the mobile HRSM uses high-speed components to atomize liquids, the following safety DANGER HIGH-SPEED ROTATION precautions must be observed at all times: 1. Read all manuals included A motionless atomizer may with this product. Be familiar appear safe, but its blade with the product and controls.
  • Page 4: Unit Preparation

    ettinG tarted npacking hecklist lectrical DO NOT OPERATE UNIT IF GROUND FAULT RECEPTACLES WARNING WARNING DAMAGED DURING SHIPPING, ARE RECOMMENDED AND MAY HANDLING OR USE. DAMAGE MAY RESULT IN BREAKAGE BE REQUIRED BY LOCAL AND/OR NATIONAL CODE. AND CAUSE INJURY OR PROPERTY DAMAGE. USE OF AN EXTENSION CORD IS NOTICE ►...
  • Page 5: Operation

    peration Fig. 2 Operation Controls The volume of fog can be regulated by adjusting the Flow Control Valve. (See Fig. 2) Particle size is smaller/drier at lower outputs, so it is Flow Control wise to operate the unit at a lower output for longer Valve periods of time rather than high outputs for short periods of time.
  • Page 6 eStinG and valuation BEFORE TESTING FAN MAKE SURE ALL OBJECTS ARE OUT DANGER OF THE ROTATION PATH OF THE FAN BLADES.HIGH-SPEED WARNING. KEEP HANDS CLEAR! MAKE SURE GUARDS ARE INSTALLED OR UNIT IS OUT OF REACH. ► For first-time evaluation, fill tank (with water only) about one quarter full. ►...
  • Page 7: Troubleshooting

    roubleShootinG BEFORE INSPECTION AND /OR SERVICE WARNING DISCONNECT AND LOCK OUT POWER SOURCE. 1. Fan Does Not Operate A.) Check voltage requirements on unit and electrical supply. Check for live receptacle, plug, power line and toggle switch. B.) Look for any loose connections inside the main motor's junction box. 2.
  • Page 8: T Roubleshooting ( Cont .)

    roubleShootinG Cont BEFORE INSPECTION AND /OR SERVICE WARNING DISCONNECT AND LOCK OUT POWER SOURCE. 6. Poor Quality Fog A.) The liquid feed tube (Part #575) may not be properly positioned. The feed tube is located behind the blade assembly and should be inserted approximately 1/4" into the slot between the motor shaft and the stainless steel face plate.
  • Page 9: A Quafog F An E Xploded V Iew

    quafoG xploded dentifiCation ID # Description Qty/Unit Housing Safety guard Liquid feed tube fitting Drain fitting 10-2000 WDD motor 115/240V // 60/50Hz Pinned venturi assembly Fan blade assembly (1 HP, 30°) Rear guard 1/4" Heavy large diameter washer 1/4-20 nylon stop nut SST SST washer for feed tube fitting 10-24 x 3/8"...
  • Page 10 600-R 600-L R e a r o f u s i 571-assy f t o l a t e S i d o t p p i v 400-047 10-2000 t o r ' s J u n c t i o n B o x 10-2000 ▼...
  • Page 11 hrSm t xploded k ' s T a n T a n i d e I n s W-38...
  • Page 12 dentifiCation dentifiCation ID # Description Qty/Unit 1/4-20 nylon stop nut SST Liquid-tight cord fitting M20 Serrated lock washer SST Fluid level gauge RSM tank Fill cap 1/2" flat washer SST 5/32 x 1 1/4" cotter pin SST 1/4" NPT close nipple T a n Inline strainer 1/4"...
  • Page 13: Maintenance

    5. Storage Protect your mobile Aquafog from winter damage. Expansion due to freezing can burst the fittings or the internal feed pump. If storing unit in below freezing temperatures, be sure all fluid is drained from the tank area. Damage due to freezing is not covered...
  • Page 14: Warranty

    Aquafog and accessories are warranted to the original purchaser against defects in material and workmanship under normal use for one full year from date of purchase. Any part determined to be defective and returned to the manufacturer, shipping cost prepaid, will be repaired or replaced at Jaybird Manufacturing, Inc.'s discretion without charge.