12
Technical data
12.1
Basic data
Boiler type
Parameters
Product Identification Number (CE number)
Length
Width
Height
Weight of the boiler body
Complete weight (empty – without condensate
box)
Transport weight unit (without condensate box)
Water content
Nominal heat output P
n
(80/60 °C as per EN 303)
Nominal heat output in condensation mode P
(50/30 °C as per EN 15034)
Maximum permissible inflow temperature
Maximum permitted operating overpressure
PMS
CO emission class (as per EN 267)
NO
emission class (as per EN 267)
X
Diameter of flue gas connection/supply air con-
nection
Voltage
Power supply frequency
Max. electric power consumption (without/with
circulation pump)
Max. electric power consumption in "Standby"
operating mode
Protection type
Tab. 12-1 Basic data A2 F
Boiler type
Burner type
Parameters
Furnace thermal capacity Q
n
Oil throughput
Heating oil
Maximum bio-heating oil content
Hydraulic system
Air regulation
Weight
Test as specified in EN 267
Voltage
Power supply frequency
Tab. 12-2 Basic data oil burner
Daikin/ROTEX A2 F
Oil condensing boiler A2 F
008.1546499_01 – 03/2018 – EN
A2 F 18H
Unit
mm
mm
mm
kg
kg
kg
109
l
kW
8.3 – 17.7
kW
c
°C
bar
mm
V
Hz
W
184 / 242
W
A2 F 18H
HLM 35 AV 16 G1 G1
Unit
kW
8.5 – 18.2
kg/h
0.72 – 1.53
EL as per DIN 51603-1 (max. sulphur content 0.1%), preferably low-sulphur
%
kg
V
Hz
A2 F 24H
CE 0085 .....
754
606
1360
63
68
97
102
114
60
56
10.6 – 24.1
85
3
3
3
3
3
80 / 125
~230
50
204 / 264
3.4
IP X0B
A2 F 24H
HLM 35 AV 19 G1 G1
10.9 – 24.7
0.92 – 2.08
10 (BTL or FAME as per DIN V 51603-6)
Modulating with oil preheating
Speed-controlled blower
9
~230
50
12
Technical data
A2 F 32H
77
111
123
50
12.5 – 31.4
3
3
228 / 289
A2 F 32H
HLM 35 AV 21 G1 G1
12.8 – 32.2
1.08 – 2.72
Installation and operating instructions
55