10

TECHNICAL SPECIFICATIONS

Unit category
Initial gas pressure
Suitable for gas
Technical data
CH
Nom. load upper value***
Nom. load lower value***
Nom. input at 80/60°C***
Nom. input at 50/30°C***
Max. CH water pressure
Max. CH water temperature
Other data
Gas consumption (G25)
Gas consumption (G20)
Gas consumption (G31)
Pressure loss of the unit (CH)
Electrical data
Mains voltage
Safety class
Absorbed power: full load
Absorbed power: part load
Absorbed power: standby
Installation measurements and weight
Height
Width
Depth
Weight
*** The maximum CH power is set in the factory. For the set value see the parameter list (& 7.2 ).
See also par. 7.3 Setting CH power.
10.1

NTC resistances

NTC 12k Ohm
T [°C]
R [ohm]
T [°C]
-15
76020
15
-10
58880
20
-5
45950
25
0
36130
30
5
28600
35
10
22800
40
ROTEX Heating Systems GmbH
C13; C33; C43; C53; C63; C83:C93
G20 : 20 mbar; G25: 25 mbar; G31: 28-50 mbar
IT, ES, CZ : II2H3P
FR
: II2Esi3P
DE
: II2ELL3P
BE
: I2E(S)
PL
: II2E3P
12
kW
3.9 – 13.1
kW
3.5 – 11.8
kW
3.4 –11.5
kW
3.8 – 12.0
bar
°C
m
/h
0.42 – 1.42
3
m
/h
0.36 – 1.22
3
m
/h
0.14 – 0.47
3
mH
O
2
V
230
IP
IP44
W
80
W
40
W
2
mm
590
mm
mm
kg
30
R [ohm]
T [°C]
R [ohm]
18300
45
5522
14770
50
4609
12000
55
3863
9805
60
3253
8055
65
2752
6653
70
2337
RHOB*AAV1H
18
6.2 – 20.8
5.6 – 18.7
5.4 –17.8
5.9 – 18.1
3
90
0.64 – 2.25
0.55 – 1.94
0.21 – 0.74
See par. 7.4
230
IP44
80
40
2
650
450
240
33
T [°C]
R [ohm]
75
1994
80
1717
85
1467
90
1266
95
1096
100
952
42
8.6 – 47.1
7.8 – 42.5
7.7 – 40.9
8.5 – 42.2
0.94 – 5.10
0.81 – 4.41
0.31 – 1.68
230
IP44
135
40
2
710
36
51