Table of Contents

Advertisement

ERR

Error information inquiry
Format
GET□ERR
/
?△ERR
Environment
Power
OFF
ON
PM
D-RGB
-
Response
Returns the current error information as
'g:ERR=<ErrorID:Character string>'
For details on other responses, refer to the "Error List".
<ErrorID:Character string>
NO_ERROR
ABNORMAL_TEMPERATURE
FAULTY_LAMP
FAULTY_LAMP_COVER
FAULTY_COOLING_FAN
FAULTY_POWER_SUPPLY
FAULTY_AIR_FILTER
FAULTY_POWER_ZOOM
FAULTY_POWER_FOCUS
FAULTY_POWER_LENS_SHIFT
FAULTY_LENS_CONNECTOR
Description
(1)
This inquires about the current error information.
(2)
This inquiry can be executed in any status provided that AC power is supplied to the projector.
(3)
Information when the warning LED of the projector is flashing can be obtained. "
returned when the warning LED is not lighted.
Example
> GET ERR or ? ERR
< g:ERR=FAULTY_LAMP
* Commands are indicated by ">", and responses are indicated by "<".
Input
A-RGB
COMP
HDMI
None
-
No error
Temperature error
Lamp error
Lamp cover error
Cooling fan error
Power supply error
Air filter error
Zoom error
Focus error
Lens shift error
Lens connector error
- 32 -
WUX5000 / WUX4000 User Commands
" is
NO_ERROR