Advertisement

Quick Links

User Manual

Advertisement

Table of Contents
loading

Summary of Contents for Chauvet Professional Ovation F-55WW

  • Page 1 User Manual...
  • Page 2 Edition Notes The Ovation F-55WW User Manual includes a description, safety precautions, installation, programming, operation and maintenance instructions for the Ovation F-55WW as of the release date of this edition. Trademarks CHAUVET, the Chauvet logo and Ovation F-55WW are registered trademarks or trademarks of Chauvet &...
  • Page 3: Table Of Contents

    Auto Programs ....................... Master/Slave ........................Dimmer Profiles......................10 LED Frequency ......................10 Back Light ........................10 System Information ......................10 Factory Reset......................... 10 5. Technical Information ..............Product Maintenance ..................6. Technical Specifications ............Photometrics Charts..................Ovation F-55WW User Manual Rev. 1...
  • Page 4 Table of Contents 7. Returns..................8. Contact Us .................. Ovation F-55WW User Manual Rev. 1...
  • Page 5: Before You Begin

    Important installation or configuration information. The product may not function correctly if this information is not used. Useful information. The term “DMX” used throughout this manual refers to the USITT DMX512-A digital data transmission protocol. Page 1 of 15 Ovation F-55WW User Manual Rev. 1...
  • Page 6: Safety Notes

    40,000 to 50,000 hours. If extending this lifespan is vital, lower the operating temperature by improving the ventilation around the product, thus reducing the ambient temperature. In addition, limiting the overall projection intensity may extend the LEDs’ lifespan. Page 2 of 15 Ovation F-55WW User Manual Rev. 1...
  • Page 7: Introduction

    2. Introduction Description The Ovation F-55WW is a warm white LED (3- inch) inkie Fresnel-style fixture ideal for short throw applications in television studios and theatres. It projects a bright, soft field of light within a 30°- 69° field angle controlled by a manual zoom.
  • Page 8: Product Dimensions

    Introduction Product Dimensions 6.81 in 173 mm 4.64 in 118.4 mm 6.53 in 166.3 mm 10.87 in 276.3 mm 3.3 in 84 mm Page 4 of 15 Ovation F-55WW User Manual Rev. 1...
  • Page 9: Setup

    Green/Yellow Green/Yellow Green DMX Linking The Ovation F-55WW will work with a DMX controller using a 5-pin DMX serial connection. A DMX Primer is available from www.chauvetprofessional.com. DMX Personalities The Ovation F-55FC uses a 5-pin DMX for its DMX personalities: 1, 2, or 5. Refer to the Introduction chapter for a brief description of each DMX personality.
  • Page 10: Mounting

    Procedure The Ovation F-55WW comes with a bracket to which you can attach a mounting clamp directly. You must supply the mounting clamps. Make sure the clamps are capable of supporting the weight of this product. Use at least one mounting point per product. For the CHAUVET Professional line of mounting clamps, go to http://www.trusst.com/products.
  • Page 11: Operation

    Knob 1 Push then turn to increase or decrease the dimmer Knob 2 Push then turn to increase or decrease the zoom Control Options Set the Ovation F-55WW starting address in the 001–512 DMX range. This enables control of up to 102 products in the 5-channel personality. Programming Refer to the Menu Map to understand the menu options.
  • Page 12: Configuration (Dmx)

    Go to the DMX Address main level. Select the starting address (001–512). The highest recommended starting address for each DMX mode is as follows: Personality Address 5 Ch 2 Ch 1 Ch Page 8 of 15 Ovation F-55WW User Manual Rev. 1...
  • Page 13: Dmx Values

    The auto programs cannot be edited. Master/Slave The Master/Slave mode allows a group of Ovation F-55WW products (the slaves) to simultaneously duplicate the output of another Ovation F-55WW (the master) without a DMX controller. To set each of the slaves: Go to the Master/Slave main level Select Slave.
  • Page 14: Dimmer Profiles

    Operation Dimmer Profiles This setting determines how fast the output of the Ovation F-55WW changes when you modify the output value. This setting provides four different options to simulate the dimming curve of an incandescent lighting product. Go to the Dimmer Mode main level.
  • Page 15: Technical Information

    Technical Information 5. Technical Information Product Maintenance To maintain optimum performance and minimize wear, clean this product frequently. Usage and environment are contributing factors in determining the cleaning frequency. Clean this product at least twice a month. Dust build-up reduces light output performance and can cause overheating.
  • Page 16: Technical Specifications

    Maximum External Temperature 113 °F (45 °C) I/O Connector Channel Range 5-pin XLR 1, 2, or 3 Ordering Product Name Item Name Item Code UPC Number Ovation F-55WW OVATIONF55WW 03031385 781462217334 Page 12 of 15 Ovation F-55WW User Manual Rev. 1...
  • Page 17: Photometrics Charts

    6.34 m 10.72 m 21.27 m 27.49 m 25 m 7.92 m 13.40 m 26.59 m 34.36 m 30 m 9.50 m 16.08 m 31.90 m 41.24 m Field Beam Field Page 13 of 15 Ovation F-55WW User Manual Rev. 1...
  • Page 18 Be sure to pack the product properly. Any shipping damage resulting from inadequate packaging will be your responsibility. FedEx packing or double-boxing are recommended. Chauvet reserves the right to use its own discretion to repair or replace returned product(s). Page 14 of 15 Ovation F-55WW User Manual Rev. 1...
  • Page 19 Visit the applicable website above to verify our contact information and instructions to request support. Outside the U.S., United Kingdom, Ireland, Mexico or Benelux, contact the dealer of record. Page 15 of 15 Ovation F-55WW User Manual Rev. 1...

Table of Contents