Page 2
Rogue R3 Beam. Trademarks Chauvet, Chauvet Professional, the Chauvet logo, and Rogue are registered trademarks or trademarks of Chauvet & Sons, LLC (d/b/a Chauvet and Chauvet Lighting) in the United States and other countries.
Table of Contents TABLE OF CONTENTS 1. Before You Begin ............... What Is Included ................... 3 Claims ......................3 Manual Conventions ..................3 Symbols ......................3 FCC Compliance......................Safety Notes....................4 Personal Safety......................Mounting and Rigging ....................Power and Wiring......................Operation ......................
Page 4
Table of Contents BL.O.Color Move......................BL.O.Gobo Move ......................Lamp Controls........................ Maintenance Timer ......................Reset Function ....................... Factory Reset Function ....................System Information ..................26 Offset Mode....................26 Pan..........................Tilt ..........................Shutter1.......................... Shutter2.......................... Color..........................Gobo ..........................Prism 1 ........................... Rotating Prism 1......................Prism 2 ...........................
Before You Begin 1. Before You Begin What Is Included • Rogue R3 Beam • 2 Omega brackets with mounting hardware ® ® • Neutrik powerCON power cable • Quick Reference Guide Claims Carefully unpack the product immediately and check the container to make sure all the parts are in the package and are in good condition.
Before You Begin Safety Notes Read all the following safety notes before working with this product. These notes contain important information about the installation, usage, and maintenance of this product. This product contains no user-serviceable parts. Any reference to servicing in this User Manual will only apply to properly trained, certified technicians.
Introduction 2. Introduction Features • Fully featured, high-powered beam fixture with a single color wheel, single static gobo wheel, layerable prisms, and 300W Ushio NSL lamp rated at 8,000 hours life • Fast and precise movement of pan and tilt functions •...
Setup 3. Setup AC Power Each Rogue R3 Beam has an auto-ranging power supply that works with an input voltage range of 100 to 240 VAC, 50/60 Hz. To determine the power requirements for each Rogue R3 Beam, refer to the label affixed to the product.
Before mounting the product, read and follow the safety recommendations indicated in the Safety Notes. For our CHAUVET Professional line of mounting clamps, go to http://trusst.com/products/. Orientation Always mount this product in a safe position, making sure there is adequate room for ventilation, configuration, and maintenance.
Setup Gobo Wheel The Rogue R3 Beam includes one gobo wheel with 17 fixed gobos plus open. The diagram shows the gobo number on the wheel, as numbered in the DMX Values tables. Open Rogue R3 Beam User Manual Rev. 5 Page 9 of 31...
Setup Color Wheel The Rogue R3 Beam includes one color wheel with 14 fixed colors plus open (white), as indicated below. The diagram shows the color number on the wheel, as numbered in the DMX Values tables. Page 10 of 31 Rogue R3 Beam User Manual Rev.
Setup Lamp Replacement The Rogue R3 Beam is equipped with an NSL Ushio 300W lamp. Follow the procedure below to safely change the lamp. Disconnect the product from power before opening. Procedure Turn the product off and disconnect it from power. Wait at least 15 minutes for the lamp to cool down.
Page 14
Setup Orient the bottom of the moving head so that the fan is facing downward. Remove the 2 wires connected to the lamp by the spade terminals.Using the lamp base, push the lamp to the left against the spring clips located on the left. Page 12 of 31 Rogue R3 Beam User Manual Rev.
Setup Roll the lamp out the top and pull it away. Reverse the steps above to install the new lamp. Do not touch the glass with bare hands. Do not turn product on without a lamp! Increasing the Lamp’s Life To prolong the life of the NSL Ushio 300W lamp, it is recommended to do the following: •...
Operation 4. Operation Control Panel Operation Button Function <MENU> Exits from the current menu or function Enables the currently displayed menu or sets the currently selected value in to the <ENTER> current function Navigates upward through the menu list or increases the numeric value when in a <UP>...
Page 17
Operation Menu Map Refer for the Rogue R3 Beam product page on www.chauvetprofessional.com for the latest menu map. Main Level Programming Levels Description Address 001–512 Sets the starting address 16CH Selects the DMX personality 19CH Auto Test Auto test all functions Pan Fine Tilt Tilt Fine...
Page 18
Operation Main Level Programming Levels Description On/Off Turns lamp on/off State/ Defines the status of lamp when powering Power On up product Off via Turns off the unit via DMX controller On if DMX Turns lamp on when DMX signal is detected Lamp Settings Off if DMX Turns lamp off when DMX signal is lost...
Operation DMX Values 19CH Channel Function Value Percent/Setting 000 255 0–100% Pan fine 000 255 Fine control (16-bit) Tilt 000 255 0–100% Tilt fine 000 255 Fine control (16-bit) Pan/tilt speed 000 255 Fast to slow Dimmer 000 ...
Page 20
Operation Channel Function Value Percent/Setting 046 048 Gobo 15 049 051 Gobo 16 052 055 Gobo 17 056 059 Open 060 063 Gobo 1 shaking, slow to fast 064 067 Gobo 2 shaking, slow to fast 068 ...
Operation 16CH Channel Function Value Percent/Setting 000 255 0–100% Pan fine 000 255 Fine control (16-bit) Tilt 000 255 0–100% Tilt fine 000 255 Fine control (16-bit) Pan/tilt speed 000 255 Fast to slow Dimmer 000 ...
Operation Manual Test This option allows each attribute to run individually or as a group. Highlight Manual Test, press <ENTER>. Highlight the desired attribute listed on the control panel screen, press <ENTER>. Set the attribute value (000–255), press <ENTER>. Repeat step 2 for the other attributes. When exiting the Manual Test level, the values of all tested channels will revert to zero.
Operation Lamp Controls This programming level allows the user to change a range of options that control the action of the lamp. • Starting from the Setup screen level, select Lamp Settings, press <ENTER>. Lamp Settings This option turns the lamp on and off. Highlight On/Off, press <ENTER>.
Operation Maintenance Timer This programming level allows the user to change a range of options that control the action of the maintenance timer. • Starting from the Setup screen level, select Maintenance Timer, press <ENTER>. Maintenance Timer Interval This option defines the amount of time (hours) that the maintenance timer will count down to. Highlight Interval Time, press <ENTER>.
Operation System Information This programming level shows standard information regarding the product’s operating status. Starting from the Main Level screen, select Sys Info, press <ENTER>. • Ver: The current software version is displayed on the screen. • Running Mode: The current Running mode is displayed on the screen. •...
Technical Information 5. Technical Information Product Maintenance To maintain optimum performance and minimize wear, clean this product frequently. Usage and environment are contributing factors in determining the cleaning frequency. Clean this product at least twice a month. Dust build-up reduces light output performance and can cause overheating.
Technical Specifications 6. Technical Specifications Dimensions and Weight Length Width Height Weight 12.79 in (325 mm) 8.66 in (220 mm) 21.65 in (550 mm) 34.4 lb (15.6 kg) Note: Dimensions in inches rounded to the nearest hundredth. Power Power Supply Type Range Voltage Selection Switching (internal)
Returns Returns Send the product prepaid, in the original box, and with the original packing and accessories. Chauvet will not issue call tags. Call Chauvet and request a Return Merchandise Authorization (RMA) number before shipping the product. Be prepared to provide the model number, serial number, and a brief description of the cause(s) for the return.