Indoor unit quiet operation. When the airflow is set to
"
", the noise from the unit will be reduced.
Note: When using Drying operation or Fan only mode, you
CANNOT adjust the airflow rate setting.
To adjust the airflow rate
1 Press
to change the airflow setting in the following
sequence.
5.3.3

Airflow direction

When. Adjust the airflow direction as desired.
What. The system directs the airflow differently, depending on the
user selection (swinging or fixed position). It does so by moving the
vertical blades.
Setting
Moves up and down.
Vertical auto swing
[—]
Stays in a fixed position.
CAUTION
▪ ALWAYS use a user interface to adjust the angles of
the flap. When the flap is swinging and you move it
forcibly by hand, the mechanism will break.
▪ Be careful when adjusting the louvers. Inside the air
outlet, a fan is rotating at high speed.
Note: The movable range of the flap varies according to the
operation mode. The flap will stop at the upper position when the
airflow rate is changed to low during the up and down swing setting.
a
b
c
Flap range in cooling or drying operation
a
Flap range in heating operation
b
Flap range in fan only operation
c
To adjust the airflow direction
1 To use auto swing, press
will appear on the LCD.
Result:
Result: The flap (horizontal blade) will begin to swing.
2 To use fixed position, press
desired position.
disappears from the LCD.
Result:
To adjust the louvers (vertical blades)
1 Hold 1 or both knobs and move the louvers.
ATXP20~35L2V1B Daikin
room air conditioner
4P513685-2 – 2017.11
Airflow direction
.
when the flap reaches the
a
Knobs
a
INFORMATION
When the unit is installed in a corner of a room, the
direction of the louvers should be facing away from the
wall. Efficiency will drop if a wall blocks the air.
5.3.4

Comfort airflow operation

This operation can be used in Heating or Cooling operation mode.
It will provide a comfortable wind that will NOT come in direct contact
with people.
To start/stop Comfort airflow operation
INFORMATION
Powerful and Comfort airflow operation CANNOT be used
at the same time. The last selected function takes priority.
If the upper or lower direction is selected, Comfort airflow
operation will be cancelled.
1 Press
to start.
Result: The flap position will change,
LCD, and the airflow rate is set to automatic.
Mode
Cooling/Drying
Heating
Note: Comfort airflow operation is NOT available in Fan only mode.
2 Press
to stop.
Result: The flap will return to the position from before the Comfort
airflow mode;
disappears from the LCD.
5.3.5

Powerful operation

This operation quickly maximizes the cooling/heating effect in any
operation mode. You can get the maximum capacity.
To start/stop Powerful operation
1 Press
to start.
is displayed on the LCD. Powerful operation runs
Result:
for 20 minutes; after that, operation returns to the previously set
mode.
Mode
Cooling/Heating/Automatic
Drying
5 Operation
a
is displayed on the
Position of flap...
Up
Down
Airflow rate
▪ To
maximize
the
cooling/
heating effect, the capacity of
outdoor unit is increased.
▪ The airflow rate is fixed to the
maximum setting.
The temperature and airflow
settings CANNOT be changed.
▪ The temperature setting is
lowered by 2.5°C.
▪ The airflow rate is slightly
increased.