3.2.3

To operate the user interface

a
a
Signal receiver
1 Aim the signal transmitter at the signal receiver on the indoor
unit (maximum distance for communication is 7 m).
Result: When the indoor unit receives a signal from the user
interface, you will hear a sound:
Sound
Beep-beep
Beep
Long beep
4

Before operation

4.1

Overview: Before operation

This chapter describes what you have to do before operating the
unit.
Typical workflow
Before operation usually consist of the following stages:
▪ Fixing the user interface to the wall.
▪ Inserting the batteries in the user interface.
▪ Changing Fahrenheit or Celsius unit setting.
▪ Turning on the power supply.
ATXP20~35L2V1B
Daikin room air conditioner
4P513685-2 – 2017.11
Description
Description
Operation starts.
Setting changes.
Operation stops.
4.2

To fix the user interface to the wall

a
b
c
a
User interface
b
Screw
c
User interface holder
1 Choose a place where the signals reach the unit.
2 Attach the holder with screws to the wall or a similar location.
3 Hang the user interface on the user interface holder.
4.3

To insert the batteries

The batteries will last for about 1 year.
1 Remove the back cover.
2 Insert both batteries at once.
3 Replace the back cover.
3
1
2
AAA.LR03
4.4
To switch between Fahrenheit and
Celsius
Change this setting only when the temperature is displayed.
1 Press
and
simultaneously for about 5 seconds.
Result: The setting changes.
4.5

To turn on the power supply

1 Turn the circuit breaker on.
Result: The flap of the indoor unit will open and close to set the
reference position.
5

Operation

5.1

Operation range

Use the system in the following temperature and humidity ranges for
safe and effective operation.
Operation mode
(a)(b)
Cooling
▪ Outdoor temperature: –10~46°C
▪ Indoor temperature: 18~32°C
▪ Indoor humidity: ≤80%
(a)
Heating
▪ Outdoor temperature: –15~24°C
▪ Indoor temperature: 10~30°C