Follow the procedure step by step to correctly diagnose the problem. Take particular care with the
checks highlighted by circled numbers, which are described in detail below:
(1)
Carry out the "Standard Setting" procedure as detailed at paragraph 9.5.5. "Standard settings".
The speed sensor detects the heads of these bolts.
(2)
Powered models:
Self-Powered models: Check the signal on ELT-01 cable. The measured signal should be
The speed signal can also be observed qualitatively, using a multimeter. The value should be 0
Vdc when the machine is stopped, and gradually increase as the speed increases.
(3)
Update the low kit SW uploading both firmware and brake table. At the end carry out the
"Default setting" procedure for the low kit parameters.
If you replace Display board/Brake board, check that its SW version is updated, otherwise
install the last version.
Pagina 6.32
SYNCHRO EXCITE 2009: Service & maintenance manual - rev. 5.2
Place the tester probes across the terminals of the speed sensor. The
measured signal should be that indicated in Figure 3.2-1. In addition,
when pedaling at 80 RPM the frequency of the signal should be 136
Hz.
that indicated in Figure 3.2-1. In addition, when pedaling at 80 RPM
the frequency of the signal should be 136 Hz.