Rear
ZRCT-100
ZRCT-200
Caution
Do not connect the UNIT OUTPUT, LINK IN, and LINK
OUT connectors to a hub. The input/output signals for
these connectors are unique to the product and are not
Ethernet signals. In particular, be aware that connecting
these connectors to a PoE injector hub may result in
damage to the product.
a UNIT OUTPUT connectors 1 to 12 (RJ-45)
Use a Category 7 cable (not supplied) to connect this
connector to the IN (unit input) connector on the
display unit you want to control (i.e., first display unit
in the daisy-chain connection).
b LINK IN connector (RJ-45)
Use this when using multiple display controllers to
control the display units.
Use a Category 7 cable (not supplied) to connect this
connector to the LINK OUT connector on the display
controller you want to link.
c LINK OUT connector (RJ-45)
Use this when using multiple display controllers to
control the display units.
Use a Category 7 cable (not supplied) to connect this
connector to the LINK IN connector on the display
controller you want to link.
d 3D SYNC OUT connector (mini-DIN, 3-pin)
Outputs 3D sync signals.
e Exhaust vent/fan
Do not block the exhaust vent, as doing so will result
in interior heat buildup which may result in fire or
malfunction.
a
m
l
a
n
m
b
c
d
k
j
i
h
g
b
c
d
k
j
i
h
g
f - IN (AC power input) connector
Use a power cord (not supplied) to connect this
connector to the circuit breaker.
g
(earth) terminal
Connect this to the earth conductor of the system.
Caution
Failure to connect the system to the protective earth
may result in electric shock. Be sure to connect to the
earth conductor, even during operation inspections.
h REF IN (external reference signal input)
connector (BNC)
Inputs external reference signals used for
synchronization.
For details, refer to the Installation Manual.
i 3D SYNC IN connector (mini-DIN, 3-pin)
Inputs 3D sync signals.
j CTRL (control) connector 2 (Mini-USB, Type B)
Use this to connect to the controller PC via a USB
(SERIAL) connection.
Use a USB cable (not supplied) to connect this to a
USB port on the controller PC.
k CTRL (control) connector 1 (RJ-45)
Use this to connect to the controller PC via an
Ethernet (LAN) connection. Use an Ethernet cable
(Category 5, not supplied) to connect this to a LAN
port on the controller PC.
7
e
f
e
f