Sony BKSI-2440 Series Installation Manual

Idc board

Advertisement

Quick Links

iDC CPU BOARD
BKSI-2440
iDC LINK INTERFACE BOARD
BKSI-2441
IDC SERIAL I/F CONNECTOR BOARD
BKSI-2042
IDC PARALLEL I/F CONNECTOR BOARD
BKSI-2043
IDC S-BUS I/F CONNECTOR BOARD
BKSI-2044
INSTALLATION MANUAL
2nd Edition (Revised 1)
Serial No. 10112 and Higher: BKSI-2440
Serial No. 10026 and Higher: BKSI-2441
Serial No. 10490 and Higher: BKSI-2042
Serial No. 10589 and Higher: BKSI-2043
Serial No. 10730 and Higher: BKSI-2044

Advertisement

Table of Contents
loading

Summary of Contents for Sony BKSI-2440 Series

  • Page 1 iDC CPU BOARD BKSI-2440 iDC LINK INTERFACE BOARD BKSI-2441 IDC SERIAL I/F CONNECTOR BOARD BKSI-2042 IDC PARALLEL I/F CONNECTOR BOARD BKSI-2043 IDC S-BUS I/F CONNECTOR BOARD BKSI-2044 INSTALLATION MANUAL 2nd Edition (Revised 1) Serial No. 10112 and Higher: BKSI-2440 Serial No. 10026 and Higher: BKSI-2441 Serial No.
  • Page 2: Bksi

    ! WARNING This manual is intended for qualified service personnel only. To reduce the risk of electric shock, fire or injury, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so. Refer all servicing to qualified service personnel.
  • Page 3: Bksi

    PRECAUTION Do not install with turning the power on Touching the power contact portion or the primary winding circuit may cause electric shock. Turn off the power and unplug the appliance from the outlet before installing. When disconnecting a connector, be careful about the edges on the connector panel Disconnecting a connector with excessive force may cause an injury of your fingers from the edges on the...
  • Page 5: Table Of Contents

    Table of Contents Manual Structure Purpose of this manual ..................3 (E) Related manual ....................3 (E) Contents ....................... 4 (E) Trademarks ......................4 (E) 1. Installation 1-1. Overview ....................1-1 (E) 1-2. Installation of the Board ................ 1-3 (E) 1-2-1.
  • Page 7: Manual Structure

    ..BKSI-2440 Maintenance Manual (Available on request) This manual describes the general service information and detailed information with the intention of servicing based on the component parts of BKSI-2440 series. For obtaining, contact to your local Sony Sales Office/Service Center.
  • Page 8: Contents

    1-8. Information of BKSI-2044 This section describes the information for BKSI-2044. 1-9. Specifications This section describes the specifications of BKSI-2040 series and BKSI-2440 series. Trademarks Trademarks and registered trademarks used in this manual are follows. . Ethernet is a registered trademark of Xerox Corporation.
  • Page 9: Installation

    Section 1 Installation 1-1. Overview Intelligent Device Controller (iDC) boards BKSI-2040 series (BKSI-2042/2043/2044) and BKSI-2440 series (BKSI-2440/2441) are installed in System Interface Unit SIU-80A/80, so as to control the devices (Network Storage System, VTR, Routing Switcher, etc.) which are used in Server Management System (SMS).
  • Page 10 iDC Concept PC with Application software SMS gateway IBM PC/AT compatible machine with BSS-1 software Ethernet i D C SIU-80A/80 Root controller CPU BKSI-2440 BKSI-2441 Device controller CPU BKSI-2440 BKSI-204x Device controller CPU BKSI-2440 BKSI-204x Device controller CPU BKSI-2440 BKSI-204x 1-2 (E) BKSI-2440...
  • Page 11: Installation Of The Board

    1-2. Installation of the Board Procedures This section describes the installation procedures for the 1. Turn the SIU-80A/80 power off and remove the front front plug-in board and rear connector panel in a System panel and shield plate. Interface Unit SIU-80A/80. (Refer to the Installation Manual supplied with SIU- For more details of each procedure, refer to the applicable 80A or SIU-80.)
  • Page 12: Connector Panel Installation

    1-2-2. Connector Panel Installation Information for inserting slot A. When the board uses for root controller Flow for installation Insert this board into the No.1 slot. It is necessary to install the one root controller board in the Start one Server Management System (SMS). Slot selection The root controller BKSI-2440 is able to control the multiple iDC boards in the one Server Management...
  • Page 13 5. When remove the connector panel, turn the power off Procedures and remove the power cord plug from the receptacle, 1. Turn the SIU-80A/80 power off and unplug the power and then remove the panel in the reverse order of steps cord from the outlet, and remove the blank panel at the 1 through 4.
  • Page 14: Connection

    1-3. Connection Connection of multiple SIU-80A/80 units installed iDC boards 1-3-1. Connection between SMS Gateway Connection is the same as the one of one SIU-80A/80. and SIU-80A/80 Install the root controller BKSI-2440 to the one SIU- Connect the BKSI-2441 installed in the rear of SIU-80A/ 80A/80, of which was connected with SMS gateway, 80 with SMS gateway (IBM PC/AT compatible machine) out of multiple SIU-80A/80 units.
  • Page 15 Connection of multiple SIU-80A/80 units installed iDC boards As an example, describes about the three SIU-80A/80 units connections. Use the BKSI-2441 installed in the rear of each SIU-80A/80, when connecting the SIU-80A/80 units. The maximum number of the connecting SIU-80A/80 units and iDC boards which are installed in each SIU-80A/80 are depended on the installing software.
  • Page 16: Information Of Bksi-2440

    1-4. Information of BKSI-2440 S700 (A-4): System setting (dip switch) This switch is used for setting of the system operation. 1-4-1. Setting and Function of Switches/ LEDs on Board The following figure shows the factory settings. Never change the setting of the switches shown by Facto- ry use only.
  • Page 17 ..Connectors ( ) marks show the address on board. Ref No. Name Function CN100 (A-5) Factory use only — CN500 (A-3) CN700 (A-3) CN1200 (A-5) CN1201 (A-4) CN1300 (D-1) CN1301 (C-6) CN400 (A-2) Compact flash card Connects the Compact flash card supplied with the main unit.
  • Page 18: Information Of Bksi-2441

    When connecting cable to connectors on the connector panel at the time of installing or servicing, use the following connector, cables or equivalents. Connectors on BKSI-2441 Matching connector/cables Panel Indication Connector Connector/cables Sony Part No. SMS GW 1 8-pin modular jack RJ-45 SMS GW 2 LAN cable (shield type) iDC LINK IN1...
  • Page 19: Signal Inputs/Outputs

    1-5-3. Signal Inputs/Outputs iDC LINK IN 2/OUT 2: D-sub 9-pin (female) Input and output signals of the connectors on the connector panel are shown below. SMS GW 1/GW 2: 100BASE-TX (8-pin modular jack) <External View> Pin No. Signal LINK IO (+) <External View>...
  • Page 20: Information Of Bksi-2042

    When connecting cable to connectors on the connector panel at the time of installing or servicing, use the following connector or equivalent. Connectors on BKSI-2042 Matching connector Panel Indication Connector Connector Sony Part No. D-sub 9-pin, Female D-sub 9-pin, Male 1-560-651-00 (connector) 1-561-749-00 (shell) 1-12 (E) BKSI-2440...
  • Page 21: Signal Inputs/Outputs

    1-6-3. Signal Inputs/Outputs 1-6-4. Switch Setting Input and output signals of the connectors on the connector IO-111 board panel are shown below. RS232C/422A 1, 2, 3, 4, 5, 6 : D-sub 9-pin (Female) COR1 COR2 COR3 COR4 COR5 COR6 <External View> Pin No.
  • Page 22: Connection Of The Rs-232C/422A Connectors

    1-6-5. Connection of the RS-232C/422A CN43, CN53, CN63, CN73, CN83, CN93 Connectors : For RS-422A (M) setting Connect these connectors when the respective RS-232C/ The respective RS-232C/422A connectors (D-sub 9-pin) 422A connectors on the connector panel are used as the on the connector panel can be set to either RS-422A (M) RS-422A controlling devices.
  • Page 23: Information Of Bksi-2043

    When connecting cable to connectors on the connector panel at the time of installing or servicing, use the following connector or equivalent. Connectors on BKSI-2043 Matching connector Panel Indication Connector Connector Sony Part No. D-sub 9-pin, Female D-sub 9-pin, Female 1-565-516-11 (connector) 1-563-379-11 (shell) 1-7-3. Signal Inputs/Outputs PIO 1, 2 : D-sub 50-pin (Female) <External View>...
  • Page 24: Information Of Bksi-2044

    When connecting cable to connectors on the connector panel at the time of installing or servicing, use the following connector, cables or equivalents. Connectors on BKSI-2044 Matching connector/cable Panel Indication Connector Connector/cable Sony Part No. BNC 75 Ω BNC 75 Ω 1-560-069-11 BELDEN 8281 cable –– 1-16 (E)
  • Page 25: S-Bus/Vs-Bus Connection Examples

    T-type bridge and 75 Ω terminator are optional accessories. T-type bridge : Sony Part No. 1-563-852-11 75 Ω terminator : Sony Part No. 1-695-542-11 • When SIU-80A/80 operating as the S-BUS primary station A connection example is shown below when the video routing switcher DVS-V6464B is used as secondary station.
  • Page 26: Specifications

    1-9. Specifications BKSI-2042 (IDC SERIAL I/F CONNECTOR BOARD) BKSI-2440 (iDC CPU BOARD) General 5 °C to 40 °C (41° F to 104 °F) Operating temperature _20°C to +60°C (_4 °F to +140 °F) General Storage temperature Operating temperature 5 dC to 40 dC (41 dF to 104 dF) Operating humidity 10 % to 90 % (no condensation) _20 dC to +60 dC (_4 dF to...
  • Page 27 BKSI-2044 (IDC S-BUS I/F CONNECTOR BOARD) General 5 °C to 40 °C (41 °F to 104 °F) Operating temperature _20°C to +60°C Storage temperature (_4°F to +140°F) Operating humidity 10% to 90% (no condensation) Dimensions (includes the connector panel) 301 × 95 × 27.5 mm (W/D/H) ×...
  • Page 29 The material contained in this manual consists of information that is the property of Sony Corporation. Sony Corporation expressly prohibits the duplication of any portion of this manual or the use thereof for any purpose other than the operation or maintenance of the equipment described in this manual without the express written permission of Sony Corporation.
  • Page 30 BKSI-2440 (SY) BKSI-2441 (SY) BKSI-2042 (SY) BKSI-2043 (SY) Printed in Japan Sony Corporation BKSI-2044 (SY) J, E 2005. 3 16 B&P Company 3-189-227-12 ©2004...

This manual is also suitable for:

Bksi-2040 seriesBksi-2440Bksi-2043Bksi-2044Bksi-2441Bksi-2042