Leds - Siemens SIMATIC NET SCALANCE X-000 Series Operating Instructions Manual

Industrial ethernet switches
Table of Contents

Advertisement

There are two TP port groups:
Group 1: P1
Group2: P2 to P5
Between ports of different port groups, an insulation voltage of 1.5 kV is adhered to
(corresponds to IEEE802.3, Chapter 33.4.1.1, Environment B), e.g. between P1 and P2.
The requirements for Environment A are met between ports of the same group, e.g. between
P2 and P5.
Devices without port groups
The following devices do not have port groups:
● SCALANCE X005
6GK5 005-0BA10-1AA3
● SCALANCE X005EEC
6GK5 005-0BA10-1CA3
The requirements for Environment A are met between all ports.
4.4

LEDs

Power LED "L" (green LED)
The power LED shows the status of the power supply.
LED color
Green
-
Port LEDs "P" (green/yellow LEDs)
The port LEDs indicate the status of the ports.
LED color
Green
Yellow
Yellow
SCALANCE X-000
Operating Instructions, 12/2018, C79000-G8976-C344-03
LED status
Meaning
Lit
Power supply is connected.
Off
Power supply is not connected or <14 V.
LED status
Meaning
Lit
TP link exists, no data reception at port
Lit
TP link exists, data reception at port
Flashing
Test phase during power on
Description of the device
4.4 LEDs