Pelican WF6/WF10 Iron/Manganese Filter and Salt Free Softener

Maintenance

Sediment Filter
It is recommended that the Sediment Filter be replaced every 6-9 months depending on the amount of
sediment present in the water supply. If the system has been working properly and the pressure is
slowing, it may be time to change the Sediment Filter. Check the Sediment Filter and replace if necessary.

Replacing the Sediment Filter

Sediment Filter Cover
Blue Filter Housing
1. Turn off the main water supply to the Sediment Filter System and bypass all tanks.
2. Run a faucet (cold water) inside the house to relieve the pressure. (Leave faucet open)
3. Unscrew the Blue Filter Housing clockwise using the supplied Filter Wrench.
4. Remove the existing Sediment Filter and discard.
5. Remove the O-Ring and wipe the groove clean. Lubricate a new O-Ring with a coating of clean
silicone grease. Replace O-Ring and press the O-Ring down into the groove with two fingers.
Note: This step is important to ensure the proper filter seal. Make sure the O-Ring is seated level
in the groove. If the O-Ring appears damaged, stretched, or crimped it should be replaced.
6. Place a new Sediment Filter onto the Stand Pipe in the Blue Filter Housing.
7. Screw the Blue Filter Housing onto the Filter Cover hand tight. Lightly snug the housing with the
spanner wrench making sure not to over-tighten.
8. Turn on main water supply slowly to allow the Sediment Filter System to fill with water and expel
air from lines. Put tanks back in service, out of bypass.
9. Check for leaks.

Chemical Injector Pump:

1. Change every 6-12 Months (Injector Pump Seal Kit - 3 O-Rings & Check Valve)
Note: Spare kits for replacement purposes can be obtained by calling your customer service
representative at Pelican Water.
Solution Tank Refill — Bleach & Water
1. Check the level of the Solution Tank twice per month. Do not let the liquid in the tank fall below
¼ full.
2. Fill the Solution Tank with bleach and treated water as needed. (Water that has gone through your
filtration system).