Chemical Injector Pump Installation; Solution Tank Installation - Pelican WF6 Owner's Manual

Iron/manganese filter & salt free softener
Hide thumbs Also See for WF6:
Table of Contents

Advertisement

Pelican WF6/WF10 Iron/Manganese Filter and Salt Free Softener

Chemical Injector Pump Installation

!IMPORTANT!
Install the Chemical Injector Pump into the water supply after the Sediment Filter and before any other
filtration or softening system.
1. Determine the size and material of your incoming water supply line from the Sediment Filter System.
2. Mount the Chemical Injector Pump to the wall using the provided bracket. Line up the inflow and
outflow connections with the current water line.
3. Remove the two red thread protectors from inlets and discard. Injector Pump has 3/4" connections,
two 1" bushings are included.
4. Plumb the Injector Pump into your water line. The arrow on the body of the Injector Pump shows
the correct water flow direction. The water should enter and exit the pump following the direction of
the arrow.

Solution Tank Installation

1. Remove the black cap from the opening on the Solution Tank.
2. Drill one 1/2" hole into the top of the Solution Tank.
3. Insert the end of the Chemical Injector Pump Tubing with the pump foot valve connected, into the
hole which was covered by the black cap on the top of the Solution Tank.
4. Feed and pull the other end of the tubing through the drilled opening on the top of the Solution
Tank.
5. Determine the length of Chemical Injector Pump Tubing required for the foot valve to reach 4" from
the bottom of the Solution Tank and cut tubing.
6. Connect the Chemical Injector Pump Tubing to the suction valve on the Chemical Injector Pump by
removing the suction hose nut, place nut over tubing, push tubing onto suction valve and tighten
nut.
7. Fill the Solution Tank with 17 gallons of bottled water and proper cups of bleach. (see chart below)
Concentration of Bleach
(% Sodium Hypochlorite)
3.00%
5.25%
6.00%
8.25%
!IMPORTANT! Ensure the Chemical Injector Pump Tubing is free of kinks and the Solution Tank is not
sitting directly on concrete. The cold temperatures held by concrete floors can separate your solution.
© 2019 Enviro Water Solutions, Inc.
3060 Performance Circle, Suite 2, DeLand, FL 32724
Number of Cups
12
7
6
4.5
Rev T
Page 14
Gallons of Water
17
17
17
17