Pushing Or Towing The Machine; Jacking Points; Tie Downs; Understanding The Diagnostic Light - Toro 03708 Operator's Manual

4-wheel drive traction unit
Table of Contents

Advertisement

turn around height or move the switch down to
decrease the lift arm turn around height. Tighten
the mounting screws.
Pushing or Towing the
Machine
In an emergency, the machine can be moved forward by
actuating the bypass valve in the variable displacement
hydraulic pump and pushing or towing the machine.
Do not push or tow the machine for more than 1/4
mile (0.4 km).
Important: Do not push or tow the machine
faster than 2-3 MPH (3-4.8 km/h) because internal
transmission damage may occur. The bypass valve
must be open whenever the machine is pushed or
towed.
Important: If the machine must to be pushed or
towed in reverse, the check valve in the four-wheel
drive manifold must also be bypassed. To bypass
the check valve, connect a hose assembly (Hose
Part No. 95-8843, Coupler Fitting No. 95-0985
[Qty. 2], and Hydraulic Fitting No. 340-77 [Qty. 2])
to the reverse traction pressure test port and the
reverse four-wheel drive pressure port.
1. Open hood and remove the center shroud
2. Rotate the bypass valve 90° (1/4 turn) in either
direction to open and allow oil to bypass internally
(Figure 43). Because fluid is bypassed, the machine
can be slowly moved without damaging the
transmission. Note the position of the valve when
opening or closing.
Figure 43
1. Bypass valve
3. Rotate the bypass valve 90° (1/4 turn) back before
starting the engine. Do not exceed 5-8 ft.-lb.
(7-11 N·m) torque to close the valve.

Jacking Points

• On the front of the machine on the frame on the
inside of each drive tire
• On the rear of the machine at the center of the axle

Tie Downs

• On each side of the frame under the front steps
• The rear bumper
Understanding the Diagnostic
Light
The machine is equipped with a diagnostic light which
indicates if the electronic controller senses an electronic
malfunction. The diagnostic light is located on the
control arm (Figure 44). When the electronic controller
is functioning correctly and the key switch is moved to
the On position, the controller diagnostic light will turn
ON for 3 seconds and turn OFF to indicate the light
is working properly. If the machine kills the light will
turn on steady until the key position is changed. The
light will blink if the controller detects a malfunction in
the electrical system. The light will stop blinking and
automatically reset when the key switch is turned to the
Off position once the fault has been resolved.
1. Diagnostic light
When the controller diagnostic light blinks, one of the
following problems has been detected by the controller:
• One of the outputs has been shorted.
• One of the outputs is open circuited.
Using the diagnostic display, determine which output
is malfunctioning; refer to Checking the Interlock
Switches.
32
Figure 44