Section 3 - Adjustments; 4602 Circuit Board Description And Adjustments - DoorKing 9150-084 Installation & Owner's Manual

9150 series vehicular slide gate operator
Table of Contents

Advertisement

The switch settings and adjustments in this chapter should be made after your installation and wiring to the operator(s) is
complete. Whenever any of the programming switches on the circuit board are changed, power must be shut-off, and then
turned back on for the new setting to take effect. Every time the 9150 is powered up, the First open command will automati-
cally run "Multiple gate cycles" that will locate and remember the gate's open and close positions (See page 23).

3.1 4602 Circuit Board Description and Adjustments

LEDs
Indicates that low voltage power is applied to the circuit board. Input LEDs should be OFF
and will only illuminate when the input is activated. Pulse LEDs will blink as the operator is
running. They can be either ON or OFF when the operator is stopped.
Auto-Close Timer
Auto-close timer (when
turned on) SW 1, switch 2.
Adjust from 1 second
(full counter clockwise) to
approximately 23 seconds
(full clockwise).
Full Open
Cycles the operator
when pressed. Gate
opens to full open
position ONLY. It will
use the Auto-Close
timer when turned ON.
Dry Relay Contact
Dry relay contacts
(terminals 15-16) can be
set for Normally Open
(NO) or Normally Closed
(NC) operation by placing
the relay shorting bar on the
N.O. or N.C. pins respectively.
SW 1, switches 4 and 5 must
be set to control relay. See
next page for descriptions.
20

SECTION 3 - ADJUSTMENTS

Dual Channel Loop Detector
SW 1
1
23
Exit Loop Port
1
2
3
FULL OPEN
4
5
6
7
8
9
10
1
11
2
3
UL 325
4
Terminal
5
Pages 25-27
6
7
14
8
9
15
10
16
17
18
DIP-Switches
SW 1
Set the DIP-switches
on the circuit board
to the desired
setting. See switch
setting charts on
next 2 pages.
9409
See page 32.
EXIT
LOOP
OPEN
TIMER
Power LED
SW3
DOORKING
UL 325
4602-010
DIP-Switches
Pages 25-27
SW1
SW2
NC
Pulse LEDs
NO
Magnetic
Sensors
See page 24.
Typical Settings
SW 1
SW 2
Single Channel Loop Detector
9410
See page 28.
Reverse Loop Port
REVERSE
SENSITIVITY
Inherent Reverse Sensor
Adjust reversing sensitivity.
Full counter clockwise for
minimum sensitivity, full
clockwise for maximum
sensitivity. See page 24.
REVERSE
LOOP
Min Max
Sensitivity
9150-065-M-5-18