Advertisement

INSTALLER'S & OWNER'S MANUAL
P/N 4029700 • Serial No.________________________ Install Date:___________
Sold by:
For small usage:
Free-standing dehumidification
n
for your home.
Includes installation, operating
n
and safety instructions, warranty
information and all ancillary
products.
Read and save these instructions.
n
420l Lien Rd., Madison, WI 53704
TOLL-FREE 1-800-533-7533
© 2015 Therma-Stor LLC •
www.Santa-Fe-Products.com
sales@Santa-Fe-Products.com TS-601 7/14/15

Advertisement

Table of Contents
loading

Summary of Contents for Santa Fe Clasic 4029700

  • Page 1 INSTALLER’S & OWNER’S MANUAL Free-standing dehumidification for your home. Includes installation, operating n and safety instructions, warranty information and all ancillary products. Read and save these instructions. P/N 4029700 • Serial No.________________________ Install Date:___________ Sold by: 420l Lien Rd., Madison, WI 53704 TOLL-FREE 1-800-533-7533 www.Santa-Fe-Products.com •...
  • Page 2: Table Of Contents

    Optional Remote Humidity Control ..........9 2.1 Location Condensate Pump Installation Instructions ....... 10 The Santa Fe Classic is designed to be installed indoors and is Ductable Inlet Mounting Detail ..........11 ideal for unfinished and finished basements. The Santa Fe Classic Muffler Kit Instructions ............
  • Page 3: A In Humid Area, No Ducting

    & ducting. If the Santa Fe Classic is located too far from a floor drain for the attached hose to reach, 1/2" PVC pipe can be used to extend 2.1C In A Remote Area, Duct Inlet & Outlet.
  • Page 4: Fan Switch

    4. Maintenance 4.1 Air Filter The Santa Fe Classic is equipped with 2 air filters. A foam pre- filter followed by a standard MERV-11 65% efficient pleated fabric filter. These should be checked every three to six months.
  • Page 5: Refrigerant Charging

    SANTA FE CLASSIC INSTALLER'S AND OWNER'S MANUAL Blower does not run with fan switch in either position. terminal 3 using an AC voltmeter. If voltage is present, go Compressor runs briefly but cycles ON & OFF. to step 3. If no voltage, the high pressure control or relay 1.
  • Page 6: C Replacing A Compressor - Nonburn Out

    SANTA FE CLASSIC INSTALLER'S AND OWNER'S MANUAL winding. If so, cautiously smell the frigerant from the check for leaks. Remove the charge and weigh in the refrigerant compressor service port for the acid odor of a burn out. quantity listed on the nameplate. Operate the system to verify performance.
  • Page 7: Wiring Diagram

    SANTA FE CLASSIC WIRING DIAGRAM 6. Wiring Diagram Figure 2: Electrical Schematic of the Santa Fe Classic Dehumidifier Santa Fe Classic Installer’s & Owner’s Manual...
  • Page 8: Service Parts List

    Optional Ducting Kit (for inlet & outlet; not shown) 4020623 Optional Outlet Collar (for ducting outlet only; not shown) 4022220 Condensate Pump Kit (see page 10) 4021586 Ductable Inlet Kit (see page 12) 4022561 Silencer Kit (see page 13) Santa Fe Classic Installer’s & Owner’s Manual...
  • Page 9: Accessories List

    8. Run the new wire to the location desired to sense relative unit, exposing 2 screws. Remove the screws. humidity. Install a 110-120 VAC dehumidistat according to local electrical codes. 3. Remove the front panel of the dehumidifier by removing 6 screws. Santa Fe Classic Installer’s & Owner’s Manual...
  • Page 10: Condensate Pump Installation Instructions

    SANTA FE CLASSIC CONDENSATE PUMP INSTALLATION INSTRUCTIONS STEP 1: The condensate pump kit STEP 2: Pre-drilled mounting holes are located STEP 3: Secure the condensate pump to the includes: drain hose, condensate pump, two near the bottom and on the same side of the unit with the two provided screws.
  • Page 11: Ductable Inlet Mounting Detail

    4. Replace the filters in the unit. 8. Using (4) screws from the kit, attach the collar to the unit. Ductable Inlet Exhaust Collar IMPORTANT! DO NOT DRILL ANY HOLES IN THE CABINET. Santa Fe Classic Installer’s & Owner’s Manual...
  • Page 12: Muffler Kit Instructions

    SANTA FE CLASSIC MUFFLER KIT INSTRUCTIONS Component List On the Santa Fe Classic, the muffler kit (1) Silencer and condensate pump kit may be used (1) #8-18 Screw together, but the pump will not be able (1) Instructions to be mounted to the unit.
  • Page 13: Filter Installation Instructions

    Foam filter with plastic grid up. Pleated filter with air flow arrows pointed down. Foam filter with plastic grid up. Pleated filter with air flow arrows pointed down. Santa Fe Classic Installer’s & Owner’s Manual Santa Fe Classic Installer’s & Owner’s Manual...
  • Page 14: Warranty

    Limited Warranty. Therma-Stor, LLC (“Therma-Stor”) warrants Customer Responsibilities. As a further condition to obtaining as follows: (i) the Santa Fe Classic dehumidifier (“Product”) will be warranty coverage hereunder, the Customer must send a valid free of material defects in workmanship or materials for a period warranty claim to Therma-Stor such that Therma-Stor receives of one (2) year (“Two-Year Warranty”) following the date of initial...
  • Page 15 1-800-533-7533 www.Santa-Fe-Products.com...
  • Page 16 1-800-533-7533 www.Santa-Fe-Products.com...

Table of Contents