The Santa Fe UltraMD33 is a built-in
dehumidification solution that can be conveniently
installed inside standard wall framing. The Santa
Fe UltraMD33 provides the ultimate in:
+ Comfort
+ Health
+ Property Protection
* Previously the Ultra Aire MD33.
800.533.7533 | Santa-Fe-Products.com
Santa-Fe-Products.com | 800.533.7533
Serial Number
Install Date
Sold By
Patent: thermastor.com/patents
Santa Fe ULTRAMD33 Installation & Operation Instructions
1
TS-1157 06/22 Rev C

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ULTRAMD33 and is the answer not in the manual?

Questions and answers

Summary of Contents for Santa Fe ULTRAMD33

  • Page 1 ULTRA SERIES | ULTRAMD33 Installation & Operation Instructions The Santa Fe UltraMD33 is a built-in Serial Number dehumidification solution that can be conveniently Install Date installed inside standard wall framing. The Santa Sold By Fe UltraMD33 provides the ultimate in:...
  • Page 2: Table Of Contents

    Controls ....................12-13 Service ....................14-16 Warranty ......................17 Warranty Card ....................18 THE SANTA FE ULTRAMD33 CONFORMS TO UNIFIED STANDARD UL 60335-2- 40 AND CSA STANDARD C22.2.60335-2-40. FOR REPAIR & TECH SUPPORT: 1-800-533-7533 (follow prompts) or CONTACT US AT: service@santa-fe-products.com Santa Fe is committed to manufacturing quality products. To maintain our standards, product specifications may change without notice.
  • Page 3: Safety Instructions

    Read the installation, operation and maintenance instructions carefully before installing and operating this device. Proper adherence to these instructions is essential to obtain maximum benefit from the Santa Fe Whole House Ventilating Dehumidifier. WARNING! 120 VOLTS MAY CAUSE SERIOUS INJURY FROM ELECTRIC SHOCK. DISCONNECT ELECTRICAL POWER BEFORE STARTING INSTALLATION OR SERVICING, AND LEAVE POWER DISCONNECTED UNTIL INSTALLATION OR SERVICE IS COMPLETED.
  • Page 4 L’UTILISATION DE L’APPAREIL À MOINS D’AVOIR ÉTÉ FORMÉES SUR L’UTILISATION DE L’APPAREIL PAR UNE PERSONNE RESPONSABLE DE LEUR SÉCURITÉ. LES ENFANTS DEVRAIENT ÊTRE SUPERVISÉS AFIN D’ÉVITER QU’ILS NE JOUENT AVEC L’APPAREIL. Santa Fe ULTRAMD33 Installation & Operation Instructions Santa-Fe-Products.com | 800.533.7533...
  • Page 5: Dehumidifier Set Up

    Check that there are no hidden wires or pipes inside the wall where unit is to be installed. Contact a certified electrician or plumber before removing any wires or pipes inside the wall. 800.533.7533 | Santa-Fe-Products.com Santa Fe ULTRAMD33 Installation & Operation Instructions...
  • Page 6: Drain Installation Considerations

    Consult local building codes for condensate drain restriction and additional requirements. The Santa Fe UltraMD33 is provided with 10' of 3/4" I.D. drain hose. Verify drain hose length is appropriate for application. The hose must be connected to the drain port and routed down the wall cavity and into the air conditioning condensate drain or other acceptable drainage.
  • Page 7: Dehumidifier Installation

    DEHUMIDIFIER INSTALLATION 1. The Santa Fe UltraMD33 can be installed in a variety of applications: • 2x6 16" O.C. Stud Wall Installation • 2x4 16" O.C. Stud Wall Installation - If penetrating both walls and the opposite side is a mechanical room, no additional accessories are needed.
  • Page 8 14". If cutting through both walls, electrical wiring and drain hose may be routed differently. Use appropriate routing for your installation. Santa Fe ULTRAMD33 Installation & Operation Instructions Santa-Fe-Products.com | 800.533.7533...
  • Page 9 The cabinet is designed to create 1/2" clearance to the back wall when installed inside a standard 2x6 stud space with 1/2" minimum drywall sheathing. 15 1/2" For alternate installations, maintain 1/2" clearance to back of wall of dehumidifier cabinet. 800.533.7533 | Santa-Fe-Products.com Santa Fe ULTRAMD33 Installation & Operation Instructions...
  • Page 10 Step 17. Install diffuser cover by aligning the lower tabs first, then setting the cover back against the wall. Insert the included four tamper resistant or Phillips screws to secure the diffuser cover. Santa Fe ULTRAMD33 Installation & Operation Instructions Santa-Fe-Products.com | 800.533.7533...
  • Page 11: Maintenance

    D’ALIMENTATION EST FERMÉ AVANT DE RETIRER LE PANNEAU AVANT POUR ENTRETENIR L’UNITÉ. 1. Filter Maintenance The Santa Fe UltraMD33 comes with a washable filter. Check filter every two months. Clean or replace the filter as necessary. • Removing the Filter: Remove the screws on the front cover and then push the front cover up gently to free the cover hooks from the chassis.
  • Page 12: Controls

    When turning power on for the first time, the set point will be at the factory setting of 55% RH. In the event of a power outage, the dehumidifier restarts at the previous set point when power is restored. Pressing the middle button (the power button), the control will toggle the Santa Fe UltraMD33 to turn ON or OFF.
  • Page 13 LED will change to Purple. The display will flash at twice the rate of “set point” mode and display the ambient temperature. Press any button to exit ambient temperature mode. 800.533.7533 | Santa-Fe-Products.com Santa Fe ULTRAMD33 Installation & Operation Instructions...
  • Page 14 UNE DÉCHARGE ÉLECTRIQUE DE 120 VOLTS PEUT CAUSER DES BLESSURES SÉRIEUSES. FERMEZ LE DIS- JONCTEUR AVANT DE COMMENCER L’INSTALLATION OU L’ENTRETIEN ET LAISSEZ LE DISJONCTEUR EN POSITION FERMÉE JUSQU’À CE QUE L’INSTALLATION OU L’ENTRETIEN SOIT COMPLÉTÉ(E). Santa Fe ULTRAMD33 Installation & Operation Instructions Santa-Fe-Products.com | 800.533.7533...
  • Page 15: Service

    (the failure • Replace compressor capacitor if failed. evaporator coil is 4. Compressor failure • Note that the sealed system is not generally warm). field serviceable. 800.533.7533 | Santa-Fe-Products.com Santa Fe ULTRAMD33 Installation & Operation Instructions...
  • Page 16 If water does not come through verify MD33 is plumb and not leaning forward or out of level. Santa Fe ULTRAMD33 Installation & Operation Instructions Santa-Fe-Products.com | 800.533.7533...
  • Page 17: Warranty

    WARRANTY Limited Warranty. Therma-Stor, LLC (“Therma-Stor”) warrants as follows: (i) the Santa Fe UltraMD33 dehumidifier (“Product”) will be free of material defects in workmanship or materials for a period of one (1) year (“One-Year Warranty”) following the date of initial purchase of such Product by an original customer purchasing from Therma-Stor or an authorized reseller (“Customer”);...
  • Page 18: Warranty Card

    WARRANTY REGISTRATION CARD REGISTER YOUR PRODUCT. PART NUMBER SERIAL NUMBER www.thermastor.com/registration Register your product using the serial number and part number above at www.thermastor.com/registration Santa Fe ULTRAMD33 Installation & Operation Instructions Santa-Fe-Products.com | 800.533.7533...
  • Page 19 I n d o o r A i r Q ua l i t Y s o lu t i o n s Santa-Fe-Products.com 1.800.533.7533...

This manual is also suitable for:

Ultra series

Table of Contents