INSTALLER'S & OWNER'S MANUAL
Free-standing Moisture Control for Large Areas
P/N 4034160 • Serial No.________________________ Install Date:___________
Sold by:
For small usage:
High capacity
n
High efficiency
n
Environmentally friendly
n
Patent pending dual-air distribution
n
4201 Lien Rd., Madison, WI 53704
Patent Pending Dual-Air Distribution
TOLL-FREE 1-800-533-7533
www.Santa-Fe-Products.com
sales@Santa-Fe-Products.com TS-833 12/13

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 4034160 and is the answer not in the manual?

Questions and answers

Summary of Contents for Santa Fe 4034160

  • Page 1 Patent Pending Dual-Air Distribution Free-standing Moisture Control for Large Areas High capacity High efficiency Environmentally friendly Patent pending dual-air distribution P/N 4034160 • Serial No.________________________ Install Date:___________ Sold by: 4201 Lien Rd., Madison, WI 53704 TOLL-FREE 1-800-533-7533 www.Santa-Fe-Products.com • •...
  • Page 2: Table Of Contents

    2. Registrations • When changing filters, do not stick fingers or other objects The Santa Fe Force conforms to UL STD 474 and CSA in the unit. standard C22.2 No. 92. • No user serviceable components. Contact installer or call 1-800-533-7533, Ext.
  • Page 3: Specifications

    After removing tie wrap, insert plastic plugs provided ducting between the Santa Fe Force discharge and the humid into the holes. room; the Santa Fe Force inlet draws air from the room in which it’s located. This works well if there is an adequate air 4.2 Location flow path between the two rooms;...
  • Page 4: Electrical Requirements

    CAUTION! a 110-120 VAC 15-Amp circuit. While operating, it draws The Santa Fe Force requires a drain trap. Creating a drain trap less than 8 amps @ 80°F, 60% RH and less than 6 amps @ allows a small amount of water to build up in the trap area of 75°F, 50% RH.
  • Page 5: Ducting

    The heat exchange coils inside the unit could If the Santa Fe Force is located too far from the floor drain and become clogged and require disassembly to the provided hose does not reach, you may use a 1/2” PVC clean.
  • Page 6: Troubleshooting

    SANTA FE FORCE OWNER’S AND INSTALLER’S MANUAL The evaporator operates in a flooded condition, which means Blower does not run with fan switch in either position. that all the evaporator tubes contain liquid refrigerant during Compressor runs briefly but cycles on and off.
  • Page 7: Wiring Diagram

    SANTA FE FORCE OWNER’S AND INSTALLER’S MANUAL 11. Wiring Diagram Santa Fe Force Installer’s & Owner’s Manual...
  • Page 8: Warranty

    Limited Warranty. Therma-Stor, LLC (“Therma-Stor”) warrants as Customer Responsibilities. As a further condition to obtaining follows: (i) the Santa Fe Force dehumidifier (“Product”) will be free warranty coverage hereunder, the Customer must send a valid of material defects in workmanship or materials for a period of one warranty claim to Therma-Stor such that Therma-Stor receives (2) year (“Two-Year Warranty”) following the date of initial purchase...
  • Page 9 1-800-533-7533. | www.santa-fe-products.com...
  • Page 12 1-800-533-7533. | www.santa-fe-products.com...