Santa Fe Advance 2 Owner's Manual

Santa Fe Advance 2 Owner's Manual

Designed for basement and crawlspace dehumidification

Advertisement

INSTALLER'S & OWNER'S MANUAL
Designed for Basement and Crawlspace Dehumidification
n
n
n
n
P/N 4034180 • Serial No.________________________ Install Date:___________
Sold by:
For small usage:
High capacity
High efficiency
Environmentally friendly
Patent pending dual-air distribution
4201 Lien Rd., Madison, WI 53704
Patent Pending Dual-Air Distribution
TOLL-FREE 1-800-533-7533
© 2014 Therma-Stor LLC
sales@Santa-Fe-Products.com TS-869 11/10/14
www.Santa-Fe-Products.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Advance 2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Santa Fe Advance 2

  • Page 1 INSTALLER’S & OWNER’S MANUAL Patent Pending Dual-Air Distribution Designed for Basement and Crawlspace Dehumidification High capacity High efficiency Environmentally friendly Patent pending dual-air distribution P/N 4034180 • Serial No.________________________ Install Date:___________ Sold by: 4201 Lien Rd., Madison, WI 53704 TOLL-FREE 1-800-533-7533 www.Santa-Fe-Products.com •...
  • Page 2: Table Of Contents

    2. Registrations • No user serviceable components. Contact installer or call The Santa Fe Advance2 conforms to UL STD 474 and CSA 1-800-533-7533, Ext. 8459 for all repair or warranty needs. standard C22.2 No.92. • Do not restrict airflow in to or out of the unit. This may cause the unit to overheat.
  • Page 3: Specifications

    3. Mount 4" above drain. Power: 640 watts @ 80°F and 60% RH 4. Do not install the Santa Fe Advance2 with the exhaust of Supply Voltage: 115 volt – 1phase – 60 Hz the unit within 1' of a wall or obstruction. Do not place the Current Draw: 5.7 amps...
  • Page 4: Electrical Requirements

    4.5 Condensate Water Removal Humid Air Dehumidified Air The Santa Fe Advance2 drains via gravity, therefore, it does not have the ability to push condensate (water) uphill. The drain hose must run downhill toward the drain location. Condensate can be drained by using the 5/8” clear vinyl hose and the 3/4”...
  • Page 5: Ducting

    If the Santa Fe Compact2 is located too far from the floor clogged and require disassembly to clean. drain and the provided hose does not reach, you may use a 1/2”...
  • Page 6: Troubleshooting

    SANTA FE ADVANCE2 OWNER’S AND INSTALLER’S MANUAL The evaporator operates in a flooded condition, which means Blower does not run with fan switch in either position. that all the evaporator tubes contain liquid refrigerant during Compressor runs briefly but cycles on and off.
  • Page 7: Wiring Diagram

    SANTA FE ADVANCE2 OWNER’S AND INSTALLER’S MANUAL 11. Wiring Diagram Santa Fe Advance2 Installer’s & Owner’s Manual...
  • Page 8: Warranty

    Limited Warranty. Therma-Stor, LLC (“Therma-Stor”) warrants Customer Responsibilities. As a further condition to obtaining as follows: (i) the Santa Fe Advance2 dehumidifier (“Product”) will warranty coverage hereunder, the Customer must send a valid be free of material defects in workmanship or materials for a period warranty claim to Therma-Stor such that Therma-Stor receives of one (2) year (“Two-Year Warranty”) following the date of initial...
  • Page 12 1-800-533-7533. | www.santa-fe-products.com...

This manual is also suitable for:

4034180