Download Print this page

GE ZGU660 Use And Care & Installation Manual page 15

Downdraft 36″ gas cooktop

Advertisement

STEP 4
PROVIDE ADEQUATE GAS SUPPLY
This cooktop is designed to operate on
natural gas at 4" of water column pressure
or on LP gas at 10" of water column pressure.
It is shipped from the factory set for natural gas.
If you decide to use this cooktop with LP gas,
conversion adjustments must be made by a
service technician or other qualified person.
A pressure regulator is to be connected in series
with the manifold of the cooktop and must
remain in series with the supply line regardless
of whether natural or LP gas is being used.
For proper operation, the maximum inlet
pressure to the regulator must be no more
than 10" water column pressure for natural
gas, or 14" water column pressure for LP
gas. For checking the regulator, the inlet
pressure must be at least 1" greater than the
regulator output setting. If the regulator is set for
4" of water column pressure, the inlet pressure
must be at least 5". If the regulator is set for 10",
the inlet pressure must be at least 11".
For ease of installation, and if local codes
permit, the gas supply line into the cooktop
should be 1/2" or 3/4" I.D. flexible metal
appliance connector three to five feet in length.
STEP 5
PREPARE FOR DUCTWORK
NOTE: Ductwork MUST be vented outside.
DO NOT vent into a wall, ceiling, crawlspace,
attic or any concealed space.
Determine the best route for ductwork;
it can be routed in a variety of ways, depending
on the kitchen layout.
Through wall to roof
Direct to rear wall
Directly through wall
Between floor joists
Cut hole in the cabinet wall or floor as
appropriate for your installation. Make sure
the exhaust duct is located between wall studs or
the floor joists.
CL
*The height
Back edge
of this hole
of cut-out
depends
on the
type of
elbow
*
6
9
used.
5"
Cut only one hole in the cabinet, depending on
the route of the ductwork.
The location of the hole is different for
left and right side venting.
Back
"
7
5
16
"
6
9
16
Vented through the left side of the cabinet
to the outside.
Vented through the right side of the cabinet
to the outside.
"
16
Back
17
"
6
9
16
"
3
8
15

Advertisement

loading

This manual is also suitable for:

Zgu661