3. Preparations Before Use

■ Receive an explanation about operation procedures and the correct method of use to ensure safe operation.
Make sure that trial operation and operation checks described in the Installation Manual have been carried out.
■ Do not stop operation except in the following instances. (Resume operation after the Lossnay unit has
been temporarily stopped.)
- When there is heavy snow, strong winds or heavy rain such as snowstorms or typhoons
- When there is thick fog
- During cleaning and maintenance
■ When a lot of humidity is generated from building materials at newly built houses, dew condensation
may form on the product and other parts. So, switch the operation mode to temporarily stop operation,
and open the windows.
■ Use the following procedure to check the positions and operation methods.
Inspection opening ... It is required for maintenance on the product. This product is installed in house attics.
So, maintenance is performed in the attic.
- If there is no inspection opening for maintenance or you find the inspection opening and product
position are out of their designated dimensions after checking the layout drawing for the inspection
opening given in the Installation Manual, contact your dealer or electrical contractor.
Grills.........They are required on the supply air and exhaust sides of the Lossnay unit. To reduce the frequency of cleaning
(Example)
the filters on the Lossnay unit, we recommend using a filter for taking up dust in the room in the exhaust grill.
Remote controller...It is required for starting and stopping operation of the Lossnay unit and for switching the fan speed.
Note:
- The Lossnay unit is not an air-conditioner.
- We recommend local ventilation for discharge cigarette smoke, etc.
- We recommend installing beds away from the supply air vent. (During sleep, you may be bothered by the operating sound
of the Lossnay unit or feel cold air.)

4. Names and Functions of Parts

Exhaust air filter case
It holds the exhaust air
filter or Medium efficiency
exhaust air filter.
Supply air filter case
It holds the supply air filter
or High efficiency supply air
filter.
Supply air filter
It removes insects, pollen,
dirt, dust, and other particles
from the outside air that is
taken into the room.
Supply air filter fixing knob
Release it to remove the
supply air filter case. (3
locations)
After the supply air filter case is
removed
Exhaust air filter
Exhaust air filter fixing knob
It prevents Lossnay core
Release it to remove the
from clogging.
exhaust air filter case. (2
locations)
Drain pan (supply air side)
It holds dew condensation
water that occurs inside the
Lossnay unit.
Lossnay core
Lossnay core exchanges
heat between the supply air
and the exhaust.
Drain outlet
It is for discharging dew
condensation water that has
built up in the drain pan to
outside the room.
Eng-3